Menu Search

Enquire Now

Give us a call for an immediate response today on any technical information, products or solutions.
Or alternatively please take a moment to fill out this form.

PHONE

Head Office:
+61 (02) 9620 8700

Melbourne Office:
+61 (03) 9589 3256

Thank you for your enquiry.

Thank you for your online enquiry, a representative from ProDetec will be in contact with you shortly. If your request is urgent please contact us on +61 2 9620 8700.

Manual Call Point

Break Glass & Push Button MCP

Search filters for Manual Call Points:
  • BExCP3ABBG Break Glass Call Point

    BExCP3A/B-BG Break Glass Call Point

    Search filters:
    Call Points

    The BExCP3A-BG and BExCP3B-BG break glass manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Available with and without monitoring resistors all versions are certified to ATEX and IECEx standards.

    More Info

  • BExCP3A PB Push Button Call Point

    BExCP3A-PB Push Button Call Point

    Search filters:
    Call Points

    The BExCP3A-PB push button manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Available without monitoring resistors all versions are certified to ATEX and IECEx standards.

    More Info

  • IS CP4ABPB

    IS-CP4A/B-PB Push Button Call Point (intrinsically safe)

    Search filters:
    Call Points

    The IS-CP4A-PB and IS-CP4B-PB push button manual call points are approved for Zones 0, 1, 2, 21 & 22 requiring intrinsically safe equipment for the control of fire and gas alarm systems. Available with and without monitoring resistors all versions are certified to ATEX and IECEx standards.

    More Info

  • GNExCP6A BG Break Glass Call Point

    GNExCP6A-BG Break Glass Call Point (GRP)

    Search filters:
    Call Points

    The GNExCP6A manual call points are available as break glass, push button or tool reset versions. They are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Available with either single or double pole change over switches. All versions are certified to ATEX and IECEx standards.

    More Info

  • GNExCP6B BG

    GNExCP6B-BG Break Glass Call Point (GRP)

    Search filters:
    Call Points

    The GNExCP6B manual call points are available as break glass, push button or tool reset versions. They are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. All types are available with EOL or series resistors, diode or Zener diodes or an LED indicator and also with either single or double pole change over switches. All versions are certified to ATEX and IECEx standards.

    More Info

  • GNExCP6B PB Push Button Call Point GRP

    GNExCP6B-PB Push Button Call Point (GRP)

    Search filters:
    Call Points

    The GNExCP6B manual call points are available as break glass, push buttonor tool reset versions. They are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. All types are available with EOL or series resistors, diode or Zener diodes or an LED indicator and also with either single or double pole change over switches. All versions are certified to ATEX and IECEx standards.

    More Info

  • GNExCP6

    GNExCP6B-PT Tool Reset Call Point (GRP)

    Search filters:
    Call Points

    The GNExCP6B manual call points are available as break glass, push button or tool reset versions. They are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. All types are available with EOL or series resistors, diode or Zener diodes or an LED indicator and also with either single or double pole change over switches. All versions are certified to ATEX and IECEx standards.

    More Info

  • GNExCP6A PT GRP

    GNExCP6A-PT Tool Reset Call Point (GRP)

    Search filters:
    Call Points

    The GNExCP6A manual call points are available as break glass, push button or tool reset versions. They are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Available with either single or double pole change over switches. All versions are certified to ATEX and IECEx standards.

    More Info

  • GNExCP6A PB GRP

    GNExCP6A-PB Push Button Call Point (GRP)

    Search filters:
    Call Points

    The GNExCP6A manual call points are available as break glass, push button or tool reset versions. They are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. Available with either single or double pole change over switches. All versions are certified to ATEX and IECEx standards.

    More Info

Contact ProDetec, call us on +61 2 9620 8700

or

Make an enquiry here