Controllers & Panels

From small wall mount stand alone controllers & panels, to medium and large more sophisticated addressable SIL2 / SIL3 certified Fire & Gas Systems.

Search filters for Control:
  • MX15a

    MX15 Low Cost single Channel Controller

    Search filters:
    Control

    The Oldham MX15 measurement and alarm controller is intended for simple installations that do not require an electrical cabinet. The Oldham MX15 controller can be connected to combustible or toxic gas detectors, or oxygen detectors.

    More Info

  • MX32a

    MX32 Single - Dual Channel Controller

    Search filters:
    Control

    Easy to install:
    - Small-sized wall-mounted box
    - Protected front face
    - Sealed polycarbonate box (IP 65)
    - Power supply 230 VAC or 115 VAC (24 VCC back-up)

    More Info

  • MX32 mod

    Cellar Monitor System for AS5034 compliance

    Search filters:
    Control

    Australian Standard AS5034-2005 (Installation and use of inert gases for beverage industry) classifies a non naturally ventilated area as any area which is neither outdoor nor naturally ventilated and then give some common example of these areas as: underground cellars and cool rooms.

    More Info

  • MX43a

    MX43 Analogue and Digital Controller

    Search filters:
    Control

    - 4 or 8 lines, up to 32 detectors
    - Up to 32 full programmable relays
    - OR, AND, NAND, NOR, Voting functions
    - Large graphic display
    - Remote modules (cost savings on wiring installation)
    - USB Data logging capability
    - RS485 Modbus RTU and multiple analogue outputs

    More Info

  • MX52a

    MX52 - 16 channel Controller (SIL2)

    Search filters:
    Control SIL2/3 rated

    Oldham MX52 16 x=channel controller accepts inputs from flammable (4-20mA transmitter or catalytic bridge types) and toxic gas detectors. The MX52 modular design allows you to build your own gas detection system to meet your requirements.

    More Info

  • MX1

    MultiSafe-MX Integrated Fire & Gas SIL2 & SIL3 Systems

    Search filters:
    Control SIL2/3 rated

    MultiSafe-MX control panel is a SIL certified fully flexible integrated fire detection, fire suppression control, gas detection, and intruder alarm system. MultiSafe-MX control panel is fully flexible integrated fire detection, fire suppression control, gas detection, and intruder alarm system. Dedicated cards determine system performance requirements.

    More Info

  • Syntel LON

    SYNTEL Fire and Gas Addressable System

    Search filters:
    Control

    Syntel is an addressable fire and gas detection and monitoring system suitable for use in zone 1 and 2 hazardous areas. The complete addressable loop is based on distributed intelligence, making it fault a tolerant system operating normally with a short or open circuit.

    More Info