Distilling

ProDetec is your pathway to monitoring key quality measuring points in your process. This results in higher product quality and less waste by giving you accurate and fast values that you can rely on to make the best decisions to keep you on top of your game. For example, to minimise product waste, you need to know that exact phase change between CIP and product.

We understand that the safety of your plant and people is paramount to you, especially if part of your process involves the potential leakage of CO2 or Alcohol. Discover how ProDetec is your partner in safety

If you can’t see your key measurement criteria below, send us a quick email with your specific needs.

Applications

Measuring turbidity is important for ensuring the quality of the final product, but also for monitoring and controlling individual process steps in the beverage and food industries. With a reliably measured turbidity value obtained during liquid analysis, you can sustainably increase the efficiency of your process

Sigrist TurbiGuard

TurbiGuard

The brewing, wine, sugar and beverage industries have the Sigrist TurbiGuard specifically designed for monitoring medium to high turbidity, in hygienic process liquids. The TurbiGuard measures turbidity using the absorption method and is typically mounted inline using a Varivent connection. The focus of the TurbiGuard is for easy installation and extremely low maintenance. There are no seals to replace and the calibration only requires a zero setting.

Sigrist TurBiScat

TurBiScat

The Sigrist TurBiScat monitors turbidity in liquids. Depending on your application, The TurBiScat can monitor turbidity at 90° and/or 25° using the highly accurate scattered light principle. There is an additional option of measuring Colour at a 430nm wavelength to monitor beer colour in EBC.

The combination of Hastelloy and sapphire in a seal-less design allows operating the unit in practically all process applications. Window fouling is monitored, compensated and can be checked using an anti-fouling control. Calibration is performed easily and at lab values of accuracy using a secondary reference standard.

Sigrist LabScat

LabScat

The LabScat monitors turbidity in liquids. Depending on your application, we can offer 90°/25° scattered light measurement with the option of Colour at a 430nm wavelength. The combination of Hastelloy and sapphire in a seal-less design allows operating the unit in practically all process applications. Turbidity measurement is done with colour compensation. Window fouling is monitored, compensated and can be checked using an anti-fouling control. Calibration is easy and very accurate with a precision optical calibration check cell, specific to each instrument.

Sigrist AquaScat 2

AquaScat 2

The AquaScat measures turbidity of potable, recycled and  raw water according to IEC 27027 using 90° scattered light detection in a non-contact, free-falling water stream. This contactless design eliminates window fouling and eliminates the need for regular maintenance (other than an annual filter change).

Calibration is performed either automatically (AquaScat WTMA) or manually (AquaScat TWM or HT) with a calibration checking unit specific to that instrument.

With a range of 0-4,000NTU, the AquaScat is sensitive enough to be used for post-filtration potable water to a heavy rain event raw water. There are 8 pre-set 4-20mA measuring ranges in the AquaScat, but any of these can be easily modified to suit your specific purpose (see the AquaScat video on setting your own measuring range).

Sigrist SICON

SICON

The control unit SICON uses state-of-the-art touch screen technology with colour display. It allows simple operation using logical menu guidance. The user can select how results are displayed, either as plain values, graphs or historical data, including the indication of system and alarm status.

The control unit SICON offers all possibilities of full system integration using various interface options. A SD card is standard and can be used for data logging with almost unlimited storage capacity.

The SICON is available as a control unit for a single instrument, or the SICON M Control Unit which allows simple operation of several instruments up to a maximum of 8 measuring channels.

ALCOHOL MONITOR is a variant of RHOTEC or SONATEC and allows measuring the content of alcohol (ethanol) in a mixture of water and ethanol. The alcohol measurement is done during the production of wine, cider and spirits.

Centec Alcohol Monitor

Alcohol Monitor

Cost-effective instrument for measuring Alcohol in a 2-component mixture

The Centec Alcohol Monitor is used to determine the alcohol content in a mixture of alcohol (ethanol) and another liquid, typically water. Centec uses density (RhoTec) or sound velocity (SonaTec) to meet your objectives. He instruments are virtually maintenance-free operation and allow for inline installation via a varivent fitting.

OXYTRANS is a very precise, optical oxygen sensor for measurement of O2 in deaerated water, wine, cider and spririts. Dissolved oxygen has adverse impact on flavour stability and shelf life.

Centec OxyTrans

OxyTrans

Optical Oxygen Sensor

The Oxygen concentration transmitter OxyTrans TR measures continuously and accurately measures the content of oxygen in liquids and gases. While the OxyTrans was originally designed for breweries, it has found service in other industries demanding these levels of accuracy, for example power plants or bioreactors.

The O2-concentration can be displayed in different units like ppb, ppm, %oxygen, etc.

The OxyTrans is available as either a transmitter installed inline (with the TR designation) or a handheld Mobile device (with the M suffix).

Colour is an important parameter not only to ensure the quality of the final product, but also for monitoring and controlling individual process steps in the beverage and food industries.

Sigrist ColorPlus 2

ColorPlus 2

Knowing the organic load of your raw water and the colour staining of your raw water intake can provide a feed-forward element of control to your water treatment process to optimise the treatment process and save money.

Until now, measuring the dissolved organics and colour required an expensive system. With the Sigrist ColorPlus the upfront cost is low enough so that your ROI is going to be much higher, much sooner.

The ColorPlus measures the colour by absorption online using up to three different wavelengths. The bypass measuring cell has been specifically designed for applications within the water industry. Depending on the configuration you select, it allows measuring DOC (UV absorption) and colour (Hazen) simultaneously while compensating for turbidity, which would otherwise influence the results

Sigrist TurBiScat

TurBiScat

The Sigrist TurBiScat monitors turbidity in liquids. Depending on your application, The TurBiScat can monitor turbidity at 90° and/or 25° using the highly accurate scattered light principle. There is an additional option of measuring Colour at a 430nm wavelength to monitor beer colour in EBC.

The combination of Hastelloy and sapphire in a seal-less design allows operating the unit in practically all process applications. Window fouling is monitored, compensated and can be checked using an anti-fouling control. Calibration is performed easily and at lab values of accuracy using a secondary reference standard.

Sigrist SICON

SICON

The control unit SICON uses state-of-the-art touch screen technology with colour display. It allows simple operation using logical menu guidance. The user can select how results are displayed, either as plain values, graphs or historical data, including the indication of system and alarm status.

The control unit SICON offers all possibilities of full system integration using various interface options. A SD card is standard and can be used for data logging with almost unlimited storage capacity.

The SICON is available as a control unit for a single instrument, or the SICON M Control Unit which allows simple operation of several instruments up to a maximum of 8 measuring channels.

Raw water quality depends greatly on its source. Based on the raw water quality and the specifications for the purified water, Centec select the most appropriate technologies for each client. Usually, multi-stage regimes are necessary for water purification

Sigrist AquaScat 2

AquaScat 2

The AquaScat measures turbidity of potable, recycled and  raw water according to IEC 27027 using 90° scattered light detection in a non-contact, free-falling water stream. This contactless design eliminates window fouling and eliminates the need for regular maintenance (other than an annual filter change).

Calibration is performed either automatically (AquaScat WTMA) or manually (AquaScat TWM or HT) with a calibration checking unit specific to that instrument.

With a range of 0-4,000NTU, the AquaScat is sensitive enough to be used for post-filtration potable water to a heavy rain event raw water. There are 8 pre-set 4-20mA measuring ranges in the AquaScat, but any of these can be easily modified to suit your specific purpose (see the AquaScat video on setting your own measuring range).

Centec Water Pre Treatment

Water Pre Treatment

Raw water quality depends greatly on its source. Based on the raw water quality and the specifications for the purified water, Centec select the most appropriate technologies for each client. Usually, multi-stage regimes are necessary for water purification.

RHOTEC L is a highly precise density sensor for determination of densities and concentrations in the laboratory (e. g. of extract in juice or alcohol in wine). The density measurement is often done for quality control.

Centec RhoTec L

RhoTec L

RHOTEC L is a highly precise sensor for determination of densities and concentrations (e. g. of extract, alcohol, sugar, acids, caustics, and solvents) according to the oscillating U-tube principle. The samples are manually injected into the sensor. The instrument is designed for laboratory applications requiring maximum sensitivity and highest accuracy.

Brix is the measurement in percentage by weight of sucrose in pure water solution. This designation of Brix degrees is only valid for pure sucrose solutions. Pure sucrose is extracted from sugar-cane or sugar-beet.

Centec Brix Monitor

Brix Monitor

Accurate monitoring of inline sugar concentration

The Centec Brix Monitor provides highly accurate monitoring of inline sugar concentration. The °Brix value of sugar syrups, soft drinks and fruit juice is performed by using either density using the RhoTec analyser or sound velocity, using the Centec SonaTec.

When installed inline, the Brix Monitor provides virtually maintenance-free and a built-in operator interface.

Centec CombiTec

CombiTec

COMBITEC is used for 3-component solutions to measure simultaneously density, sound velocity and concentration e. g. in a mixture of acid and salt in water or in systems such as sulfuric acid/oleum or methanol/formaldehyde.

ProDetec has access the the worlds best gas detectors for a wide range of industries.  Whether the need is for a single application or multiple sites and areas, our durable gas monitoring solutions meet your unique industrial needs. We offer a broad range of gas detectors and controllers to satisfy international certification standards such as  SIL (Safety Integrity Level), Marine, IECEx.

Teledyne Oldham Simtronics GD10P CO2 Gas Detector

GD10P CO2 Gas Detector

 The Infrared (IR) gas detectors differ from all other models, because they utilise silicon based solid-state infrared sources. The complete opto-mechanical design construction is so stable that an ultra fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.
The Simtronics GD10 Series of gas detector offers the longest combined detector and IR source warranty on the market: 5 years warranty & 15 years on IR sources.

Teledyne Oldham Simtronics CTX300 Gas Detector

CTX300 Gas Detector

When hazardous levels of toxic gases or oxygen threaten the safety of an unclassified area, the CTX 300 detector can satisfy the most demanding safety requirements. The CTX 300 detector is designed to detect oxygen, toxic and refrigerant gases, and also uses a new sensor for CO2 detection over three different ranges: 0-5000 ppm, 0-5% vol. and 0-100% vol. 

Teledyne Oldham Simtronics GD10P Hydrocarbon Infra Red Point Gas Detector

GD10P Hydrocarbon Infra Red Point Gas Detector

The Simtronics GD10P detector is the benchmark for combustible gas detection for offshore oil and gas installations. It has set the standard for gas detectors in the areas of safety, stability and low maintenance both onshore & offshore. 

The GD10P has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations. 

These IR gas detectors differ from all other models, because they utilise silicon based solid-state IR sources. The complete opto-mechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. 

We offer the longest combined detector and IR source warranty on the market. 

For retrofit applications, a bridge interface is available allowing the detector to be connected directly to catalytic systems, using cabling and control modules. 

Teledyne Oldham Simtronics iTrans2 Gas Detector

iTrans2 Gas Detector

The iTrans2 infrared gas detector employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance, and lower installation costs. With the optional HART Communication Protocol, the iTrans2 offers remote diagnostics, set-up, or calibration by superimposing a high-frequency current across the industry standard 4-20mA analog line.

Teledyne Oldham Simtronics OLCT100 Gas Detector

OLCT100 Gas Detector

Designed for the detection of explosive gases, toxic gases or oxygen, this combustible gas detector comes with Wheatstone bridge output (OLC 100) or 4-20mA output (OLCT 100). Whatever your application ProDetec offers a solution: catalytic, electrochemical, semiconductor, or poison control version. IEC Ex approved, these detectors are available in explosion safe or intrinsically safe versions. SIL 2 certified according to EN 50402.

Teledyne Oldham Simtronics MX32 Multi Channel Controller

MX32 Multi Channel Controller

The new MX 32, a controller that takes analog & digital inputs and covers all needs for a wide variety of applications. The MX 32 is a compact, low-profile controller that continuously monitors gas detection and more generally any 4-20 mA, MODBUS RS485 signal from compatible detectors.

Teledyne Oldham Simtronics MX43 SIL-1 Certified Gas Detection Controller

MX43 SIL-1 Certified Gas Detection Controller

SIL-1 Certified MX 43 is a Flexible, High Quality, Easy to Use Gas Detection System 

Fully scalable, and designed to functional safety performance level 1 standards, the MX 43 is an analog and digital controller that continuously measures and controls gases in the atmosphere. The MX 43 gas detector manages both digital lines and analog channels and covers all needs for a wide variety of gas monitoring applications. The MX 43 digital technology allows up to 32 detectors to be distributed on 8 lines for increased cost savings. 

Teledyne Oldham Simtronics MX52 2- 16 Channel Gas Detection Controller

MX52 2- 16 Channel Gas Detection Controller

The MX 52 control unit allows various detectors to be connected and monitored. Any gas detector from Teledyne Gas and Flame Detection or any other 4-20 mA device can be monitored and controlled. The modular design and flexibility enable this MX 52 gas detection equipment to be adapted to your exact requirements.

ProDetec can offer our customers innovative portable gas detectors that offer greater reliability, improved productivity, and better cost-efficiency to protect your workers from potential gas hazards. These gas detectors can be readily calibrated and tested on site with the aid of Automated Calibration and Bump Testing Stations.

Gas Clip MGC Simple Clip Dock

MGC Simple Clip Dock

The Gas Clip Technologies MGC Simple Clip Dock is an all-in-one, stand-alone docking station designed for maximum testing efficiency and portability. It tests up to four detectors simultaneously, reducing the testing time and gas usage.

Gas Clip Multi Gas Clip Dock

Multi Gas Clip Dock

The Gas Clip Technologies MGC Dock is an all-in-one stand-alone docking station designed for maximum testing efficiency and portability. It tests up to four detectors simultaneously, reducing the testing time and gas usage.

Gas Clip Multi Gas Clip Infrared

Multi Gas Clip Infrared

The MGC IR detects combustible gases (LEL), hydrogen sulphide (H2S), carbon monoxide (CO) & oxygen (O2). The MGC IR can go a full 2 months without a charge, even without ever having to be turned off. Shut down the detector nightly and the battery can last up to 4 months.

Gas Clip Multi Gas Clip Pump Infrared

Multi Gas Clip Pump Infrared

Like the MGC IR, the MGC IR Pump uses low-power photometric infrared technology to detect combustible gases (LEL) rather than age-old pellistor technology. The MGC IR Pump uses an IR source which conserves power and helps the battery last and last.

Gas Clip Multi Gas Clip Simple

Multi Gas Clip Simple

4 gas detector with 2 year runtime. No charging ever! Reliably test for hydrogen sulphide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL) with this simple-to-use and simple-to-maintain detector. Just turn it on and have worry free assurance of protection against toxic gases 24/7 for two full years.

Gas Clip Multi Gas Clip Simple Plus

Multi Gas Clip Simple Plus

No charging ever! 3 Year runtime. Reliably test for hydrogen sulphide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL) with this simple-to-use and simple-to-maintain detector. Just turn it on and have worry free assurance of protection against toxic gases 24/7 for three full years.

Teledyne GMI Protege ZM Single Gas Monitor

Protege ZM Single Gas Monitor

The GMI Protege ZM Single Gas Monitor is an easy-to-use, zero maintenance gas detection solution that delivers high performance in a small, ergonomically designed package. It is available in oxygen, carbon monoxide and hydrogen sulphide single gas models. This single gas monitor is incredibly reliable, giving industrial workers and first responders the confidence to focus on the task at hand, not on their equipment.  

Teledyne GMI PS200 4 Gas Monitor

PS200 4 Gas Monitor

The PS200 Multi Gas Detector combines quality, ruggedness, and advanced technology in a user friendly, portable gas monitor. It is compact, lightweight, water resistant, extremely robust, and is certified to multiple international and regional standards. 

The PS200 can measure any combination of LEL, O2, CO and H2S making it suitable for a wide range of personal monitoring and confined space applications. 

In addition to extensive data logging capabilities, the PS200 is available with an optional internal pump and an extensive range of accessories to meet a wide variety of user applications. 

Teledyne GMI PS200 ABC Station

PS200 ABC Station

The multi-functional Auto Bump/Calibration station provides simple but intelligent testing and calibration of the PS200 portable gas detector. Easy to use, with a durable, user friendly design, this automated test station offers high performance from a PC or stand-alone unit.

Teledyne GMI PS500 5 Gas Monitor

PS500 5 Gas Monitor

Designed by our customers, this robust and accurate gas detector provides unrivalled protection in confined space applications. The PS500 can be tailored to detect up to five gases with its toxic and catalytic sensors, photo ionisation detectors, and infrared capabilities. “Plug and Play” option allows the customer to “plug in” a new board with a different gas range.

Teledyne GMI PS500 ABC Station

PS500 ABC Station

To provide accurate performance and results, the PS500 has to be properly used and maintained. The Auto Bump & Calibration Station (ABC) provides bump testing, calibration and data management options and is compact, robust and intuitive to use.

Teledyne GMI PS500 CO2 Gas Monitor

PS500 CO2 Gas Monitor

The PS500 can be tailored to detect up to five gases with its toxic and catalytic sensors, photo ionisation detectors, and infrared capabilities. “Plug and Play” option allows the customer to “plug in” a new board with a different gas range.

Gas Clip Single Gas Clip

Single Gas Clip

Whether it’s the hottest or the coldest environment, our Single Gas Clip is designed and tested to provide worker safety in the harshest working conditions. Gases available are hydrogen sulphide (H2S), carbon monoxide (CO), oxygen (O2).

Gas Clip Single Gas Clip Dock

Single Gas Clip Dock

Gas Clip Technologies Single Gas Clip Dock is an all in one docking station designed for maximum testing efficiency and portability. Housed in a rugged case with robust USB memory, this station will be able to accurately test and record all monitor data while reducing the testing time and gas usage.

ProDetec Calibration and Test Gas 44 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder

44 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder

Recyclable 44 litre cylinders available for reactive gas mixtures, supplied with either a single gas or a complex blend.

Most commonly supplied in 4 or 5 gas mixtures such as CH4, O2, CO, H2S with either SO2 or CO2

Also available in single fills containing H2S, NH3, PH3, HCN, HCL, SO2, NO2, NO in either air or nitrogen. Some reactive gases will have a shorter life – typically 12 months.

ProDetec Calibration and Test Gas 66 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder

66 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder

Recyclable 66 litre cylinders available for reactive gas mixtures, supplied with either a single gas or a complex blend.

Most commonly supplied in 4 or 5 gas mixtures such as CH4, O2, CO, H2S with either SO2 or CO2

Also available in single fills containing H2S, NH3, PH3, HCN, HCL, SO2, NO2, NO in either air or nitrogen. Some reactive gases will have a shorter life – typically 12 months.

ProDetec Calibration and Test Gas 103 Litre Steel Non-Reactive Single Gas Calibration Gas Cylinder

103 Litre Steel Non-Reactive Single Gas Calibration Gas Cylinder

Disposable cylinders available for non reactive gas mixtures, supplied with either a single gas up to three non reactive gas mixtures

Most commonly supplied in single fills containing Argon, Benzene, Butane, Carbon Dioxide, Carbon Monoxide, Ethane, Ethylene, Freon, Helium, Hexane, Hydrogen, Isobutane, Isobutylene, Methane, Nitrogen, Oxygen, Pentane, Propane, Toluene in either Air or Nitrogen backgrounds. Warranty on these gases is 48 months.

 

ProDetec Calibration and Test Gas 116 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder

116 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder

Recyclable 116 litre cylinders available for reactive gas mixtures, supplied with either a single gas or a complex blend.

Most commonly supplied in 4 or 5 gas mixtures such as CH4, O2, CO, H2S with either SO2 or CO2

Also available in single fills containing H2S, NH3, PH3, HCN, HCL, SO2, NO2, NO in either air or nitrogen. Some reactive gases will have a shorter life – typically 12 months.

ProDetec Calibration and Test Gas Regulators and Accessories

Regulators and Accessories

Regulators for non-refillable cylinders are available in a number of different configurations including fixed flow, push button, on-demand flow and variable flow models.

ProDetec Calibration and Test Gas Gas Recycling Program

Gas Recycling Program

Once the calibration gas cylinders are relieved of pressure they are NOT considered hazardous material or waste. Nearly all of our mixtures contain only a very small amount of a hazardous chemical(s) as a minor component in the gas mixture requested. The fact that it is such a small amount (usually in the ppm range) always precludes the gas mixture from ever being classified as hazardous.

Our calibration gas cylinder recycling program is an environmentally-friendly way to reduce waste caused by empty cylinders. We offer a free, easy way to return used cylinders for future use.

At ProDetec we can supply specialised gases and gas mixtures to meet various and specific requirements. We work with you to understand your application and analyse your consumption patterns. This way we can offer the correct cylinder size that maximises your efficiency while minimising costs.

During truck unloading the product can get charged electrostatically. This way the truck itself will be charged up, too (if the product is charged negatively, the truck will have a positive load). As a truck has a relatively large electric capacity, this may lead to very powerful spark discharges.

Stuvex TES01 Truck Earthing System

TES01 Truck Earthing System

Loading and unloading of tanker trucks with liquids or powders can generate static electricity that could cause sparks discharging. The Stuvex TES01-V2 earthing verification system has been designed to detect a low electrical resistance between the clamp jaws that are attached to the truck’s earthing point. 

Stuvex S604 and S804 Static Discharge Systems

S604 and S804 Static Discharge Systems

An electrostatic charge can be generated while handling conductive liquids or powders.  A resistive system (S604) recognises the low conductive resistance of the object and of fixed installations. It is meant for general use with barrels, carts, metal objects. Uncontrolled electrostatic discharge when filling or unloading big bags is a frequent source of ignition. The earthing Control System (S804) recognises the conductivity of an FIBC (Big Bag) type C.

Stuvex RSV Fast Shutting Gate Valve

RSV Fast Shutting Gate Valve

RSV fast shutting gate valves prevent propagation of dust explosions by blocking the shock wave and flame. RSV fast shutting gate valves are active valves closing in a matter of milliseconds when triggered by a spark or explosion detector. 

Where more stringent hygienic standards apply, sterilization-in-place (SIP) is done after CIP cleaning. SIP kills harmful microorganisms that may have survived CIP or in cases where Cleaning-in-Place is not performed.

Centec Sterilization in Place

Sterilization in Place

Where more stringent hygienic standards apply, sterilization-in-place (SIP) is done after CIP cleaning. SIP kills harmful microorganisms that may have survived CIP or in cases where Cleaning-in-Place is not performed.

The purpose of Cleaning-in-Place (CIP) is to remove product residues and microorganisms from all wetted surfaces inside tanks, pipework and filling machines. Centec provide CIP skids for cold and hot cleaning in beverage industry.

Centec Cleaning in Place

Cleaning in Place

The purpose of Cleaning-in-Place (CIP) is to remove contaminations from wetted surfaces inside tanks, pipework and filling machines. A CIP cycle consists of various steps, e. g. pre-rinse with water, flushes with caustics and acid solutions, intermediate and final rinse with water.

Dust explosions can occur frequently in industrial processes where combustible material is transported/ pneumatically or mechanically conveyed, heated, filtered, spray dried, milled and stored

Stuvex StuVent Explosion Venting

StuVent Explosion Venting

The oldest and most frequently used explosion protection technique is explosion venting. That means that weak points are deliberately introduced in the equipment in a controlled way. In case of an explosion, these weak points will open, and the explosion pressure is released. It is not easy to calculate and correctly position the right venting surface. 

Stuvex VENTEX Passive Isolation Valve

VENTEX Passive Isolation Valve

Ventex explosion isolation valves prevent propagation of dust explosions by blocking the shock wave and flame front. Ventex valves are passive valves meaning they will close without requiring any external input. 

Stuvex RSV Fast Shutting Gate Valve

RSV Fast Shutting Gate Valve

RSV fast shutting gate valves prevent propagation of dust explosions by blocking the shock wave and flame. RSV fast shutting gate valves are active valves closing in a matter of milliseconds when triggered by a spark or explosion detector. 

Stuvex NOVEX Passive Explosion Isolation Flap Valve

NOVEX Passive Explosion Isolation Flap Valve

The NOVEX series is a protective system consists of passive non-return flap valves for the explosion isolation of combustible dust. The main application for the NOVEX valves is for explosion isolation on pipelines at inlet of dedusting filters operating under vacuum and protected by autonomous explosion vent panels. 

Stuvex Flash Explosion Suppression System

Flash Explosion Suppression System

Based on the Flash explosion suppression system and operating in a similar manner, Flash chemical barriers are capable of detection an explosion in an early stage by means of pressure or flame detectors. 

Firefly Firefly Spark Detection Systems

Firefly Spark Detection Systems

Firefly’s Spark and Hot Body Detectors are designed to detect ALL potential ignition sources such as sparks, glowing and hot particles. These detectors are insensitive to daylight minimising false alarms.

Firefly Firefly Fast Water Mist Systems

Firefly Fast Water Mist Systems

Firefly PowerImpact™ extinguishing is used in process ducts and chutes, it has a unique design spraying from different directions into a chute or duct utilising Full cone spray nozzles. Large water droplets for more momentum and penetration with a minimum of three water nozzles and solenoid valves per zone. Each water nozzle uses a Quick-connection and flexible hose that makes it easy to test the system without releasing water into the process

Firefly Water Mist Suppression Systems have remarkable flame suppression capabilities, utilising a small amount of water. The unique design of the hydraulic system enables a very quick system response time.

Audible, Visual Sounders and Sirens are used for alert and alarm purposes in the process, mining and industrial applications

Filter products Showing 1 - 12 of 53 results
Filter
E2S BExS110 Ex d Alarm Horn – Radial Omni-directional

BExS110 Ex d Alarm Horn – Radial Omni-directional

The flameproof BExS110 alarm sounders are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards.

The BExS110-R is an alarm sounder featuring a radial omni-directional horn that disperses the alarm tones radially. Ideal for applications requiring a compact audible signalling solution.
The BEx explosion proof Ex d range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with chromate and powder coat finish.

 

E2S A105N Alarm Sounder

A105N Alarm Sounder

The A105N is a high output, 112dB(A) alarm sounder. UL and GOST-R approved and tested to EN54-3 for CPR compliance (89/106/EEC) for fire alarm use. For marine applications the A105N is MED approved.

Low current consumption and high SPL in a robust fire retardant IP66 housing ensure the A105N is suitable for all general signalling applications including fire, security and process control.

E2S A100 Alarm Sounder

A100 Alarm Sounder

The A100 is a compact, high output, 104dB(A) alarm sounder. CPR complaint, EN54-3 tested and UL approved. Featuring 32 alarm tone frequencies and 3 remotely activated stages/channels.

Low current consumption and high SPL in a robust fire retardant housing ensure the A100 is suitable for all general signalling applications including fire, security and process control. The A100 is a member of the versatile AlertAlarm family of industrial alarm horn sounders – also available with Xenon, AL100X or LED beacons, AL100H.

E2S A112N Alarm Sounder

A112N Alarm Sounder

The A112N is a high output, 119dB(A) alarm sounder. UL and GOST-R approved and tested to EN54-3 for CPR compliance (89/106/EEC) for fire alarm use. For marine applications the A112N is MED approved.

High SPL in a robust fire retardant IP66 housing ensure the A112N is suitable for all general signalling applications including fire, security and process control.

E2S A121 Alarm Sounder

A121 Alarm Sounder

The A121 is a very high output, 126dB(A) alarm sounder. UL and GOST-R approved and tested to EN54-3 for CPR compliance (89/106/EEC) for fire alarm use.

High SPL in a robust, fire retardant IP66 housing ensure the A121 is suitable for all general signalling applications including fire, security and process control.

E2S A131 High Level Audible Warning System

A131 High Level Audible Warning System

The A131 is a high output 131dB(A) @ 1 metre electronic siren in a compact and easy to install package. Using up to four speakers, it can be mounted in a variety of ways for applications with sound coverage requirements up to 300m.

The A131 modular system is ideal as a plant alarm to cover outdoor locations, areas with high background noise or smaller COMAH (Seveso II) applications. Offering a choice of three alarm stages, selected from a choice 45 tones including many national standard tones, it can be incorporated in fire, security and general alarm systems where existing equipment is not powerful enough or the system needs expanding.

E2S A141 High Level Audible Warning System 141dB(A)

A141 High Level Audible Warning System 141dB(A)

The A141 is the latest in a new generation of high output electronic sounders from E2S which are ideal for wide area and disaster warning applications requiring sound coverage up to 750m.

With a choice of 45 standard warning tones including many international signals the A141 is also available in a ‘Stage Programmable’ version which can offer up to 4 remotely activated stages of alarm. Typical installation include COMAH (Seveso II) Alarm, Toxic Gas Release, Fire, Security, Flood Warning, Tsunami Alert and Civil Defence.

E2S BExS110 Explosion Proof Alarm Horn Sounder

BExS110 Explosion Proof Alarm Horn Sounder

The flameproof BExS110 alarm sounders are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards. Available as SIL 1 and SIL 2 compliant.

Sound level outputs of up to 117dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages.
The BEx explosion proof Ex d range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with chromate and powder coat finish.
Available in MED approved and SIL2 compliant versions.
For fire applications the BExS110D 24V dc siren is CPD EN89/106/EEC compliant (EN54-3 tested).

E2S BExS120 Explosion Proof Flare Horn Alarm Sounder

BExS120 Explosion Proof Flare Horn Alarm Sounder

The flameproof BExS120 alarm sounders are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards.

Sound level outputs are up to 123dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages.
The BEx explosion proof Ex d range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with chromate and powder coat finish.
For fire applications the BExS120D 24V dc siren is CPD EN89/106/EEC compliant (EN54-3 tested).

E2S BExH120 ‘Hootronic’ Explosion Proof Alarm Horn

BExH120 ‘Hootronic’ Explosion Proof Alarm Horn

The flameproof BExH120 Hootronic Siren is suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards. The BExH120 authentically reproduces the traditional sounds of electro-mechanical devices whilst providing a significantly higher level of performance and reliability.

The E2S Hootronic series of products faithfully reproduce the sounds made by legacy electro-mechanical signalling devices but in a modern, reliable and cost effective way. With output levels of up to 117.5dB(A) at 1 metre the BExH120 surpasses legacy electro-mechanical devices in performance and effectiveness, it is also continuously rated, requires zero maintenance and the signal quality will not degrade with age.

E2S BEx Plated Assemblies

BEx Plated Assemblies

The BEx explosion proof Ex d family of alarm horn sounders, Xenon strobe and LED beacons can be configured to create sets of status lights suitable for onshore and offshore applications.

Mounted onto a stainless steel backplate, E2S can offer up to 5 different components complete with the option of Exe Junction Box to simplify installation. Status lights configurations can utilise the high power BExBGL2 LED beacon. Warning beacons utilising Xenon strobe technology – available in 5, 10, 15 and 21J outputs (up to 485 Cd) and providing effective warning in all conditions.

Manual alarm call points are designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by operating the push button or break glass the alarm signal can be raised.

E2S BExCP3-BG Break Glass Manual Call Point

BExCP3-BG Break Glass Manual Call Point

The BExCP3-BG break glass manual call points are designed for the harshest of environments and approved for Zone 1, 2, 21 and 22 explosion proof hazardous areas for the control of fire and gas alarm systems. SIL2 compliant to IEC61508 (2010).

The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium with a chromated and powder coat finish. Available with and without monitoring resistors all versions are certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The break glass element features a safety membrane and is designed to snap ensuring the no glass fragments are released during activation. A hammer is available as an accessory if required by local code.

E2S BExCP3-PB Push Button Manual Call Point

BExCP3-PB Push Button Manual Call Point

The BExCP3-PB push button manual call points are designed for the harshest of environments and approved for Zone 1, 2, 21 and 22 explosion proof hazardous areas for the control of fire and gas alarm systems. SIL2 compliant to IEC61508 (2010).

The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium with a chromated and powder coat finish. Available with and without monitoring resistors all versions are certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The BExCP3-PB is user re-settable by rotating the push button.

E2S GNExCP6-BG Break Glass Manual Call Point

GNExCP6-BG Break Glass Manual Call Point

Available with optional EOL or series resistors, diode or Zener diodes and an LED indicator. Also with either single or double pole change over switches. Certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The break glass element features a safety membrane and is designed to snap ensuring the no glass fragments are released during activation. A hammer is available as an accessory if required by local code.

The flameproof GNExCP6-BG break glass manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. The robust, lightweight GRP enclosure is UV stable and provides a corrosion free initiation solution for harsh and hazardous applications on and offshore.

E2S GNExCP6-PB Push Button Manual Call Point

GNExCP6-PB Push Button Manual Call Point

The flameproof GNExCP6-PB push button manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. The robust, lightweight GRP enclosure is UV stable and provides a corrosion free solution for initiation in harsh and hazardous applications on and offshore.

Available with optional EOL or series resistors, diode or Zener diodes and an LED indicator. Also available with either single or double pole change over switches. Certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The GNExCP6-PB is user re-settable by rotating the push button.

E2S IS-CP4-PB Push Button Manual Call Point

IS-CP4-PB Push Button Manual Call Point

The IS-CP4-PB push button manual call points are designed for the harshest of environments and approved for Zones 0, 1, 2, 21 & 22 requiring hazardous area intrinsically safe equipment for the control of fire and gas alarm systems. SIL2 compliant to IEC61508 (2010).

The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is chromated and powder coated. Available with and without monitoring resistors all versions are certified to IECEx and ATEX standards with additional INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The IS-CP4-PB is user re-settable by rotating the push button.

E2S GNExCP6-PT Push Button Tool Reset Call Point

GNExCP6-PT Push Button Tool Reset Call Point

The flameproof GNExCP6-PB tool reset push button manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. The robust, lightweight GRP enclosure is UV stable and provides a corrosion free solution for initiation in harsh and hazardous applications on and offshore.

Available with optional EOL or series resistors, diode or Zener diodes and an LED indicator. Also available with either single or double pole change over switches. Certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The GNExCP6-PT is user re-settable via the use of the special key supplied with the unit.