Low current consumption and high SPL in a robust fire retardant housing ensure the A100 is suitable for all general signalling applications including fire, security and process control. The A100 is a member of the versatile AlertAlarm family of industrial alarm horn sounders – also available with Xenon, AL100X or LED beacons, AL100H.

Category: Tag:

Description

Technical Description – A100 Alarm Sounder

Features

  • Automatic synchronisation on multi-sounder system.
  • Continuously rated.
  • Stainless steel fixings.
  • Unit can be mounted using external lugs or internal BESA compatible fixing positions.
  • Duplicate cable terminations (in & out for daisy-chain installations).
  • Tropicalisation available on request.
  • Available with custom tone configurations and frequencies.
  • Stage programmable version available:
    • 45 alarm tones
    • 4 remotely selectable stages
    • Any tone can be assigned to any stage
    • User configurable continuous frequency tone

 

Specification

Maximum output: 104dB(A) @ 1 metre [95dB(A) @ 10ft/3m]
Nominal output: 100dB(A) @ 1m +/- 3dB – Tone 2 [91dB(A) @ 10ft/3m]
No. of tones: 32 (UKOOA / PFEER compliant)
No. of stages: 3
Volume control: Max. 100dB(A);
Min. 90dB(A) – Tone 2
Effective range: 32m/105ft @ 1KHz
Voltages DC: 24V dc (10-30V dc);
48V dc (35-60V dc)
[DC units can use 24V ac for single stage applications.]
Voltages AC: 24V ac; 115V ac; 230V ac
Stage switching: Negative
Reverse polarity stage switching on DC units.
Ingress protection: IP66
Housing material: High impact UL94 V0 & 5VA FR ABS
Colour: Red (RAL3000), grey (RAL7038) & white.
Cable entries: 3 x M20 clearance gland entries in side & back
Terminals: 0.5 to 1.5mm² cables.
Operating temp: -25 to +55°C [-13 to +131°F]
Storage temp: -40 to +70°C [-40 to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 0.26kg/0.57lbs AC:0.37kg/0.81lbs

 

Current Consumption

Version: Voltage: Current:
24V dc 10-30V dc 25mA*
48V dc 35-60V dc 50mA*
24V ac 50/60Hz +/-10% 40mA
115V ac 50/60Hz +/-10% 20mA
230V ac 50/60Hz +/-10% 15mA
* current at nominal voltage on Tone 2

 

Please refer to data sheet for more information

Data Sheet – A100 Alarm Sounder

Manual - A100 Alarm Sounder

Hover Box Element

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

A100 Sounder Range - Outline

Hover Box Element

A100 Standard Sounder Range - Outline

Hover Box Element

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

EU Declaration of Conformity

Hover Box Element

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Declaration of Performance

Hover Box Element

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.