A105N Alarm Sounder

The A105N is a high output, 112dB(A) alarm sounder. UL and GOST-R approved and tested to EN54-3 for CPR compliance (89/106/EEC) for fire alarm use. For marine applications the A105N is MED approved.

Low current consumption and high SPL in a robust fire retardant IP66 housing ensure the A105N is suitable for all general signalling applications including fire, security and process control.

Category: Tag:

Description

Technical Description – A105N Alarm Sounder

Features

  • Automatic synchronisation on multi-sounder system.
  • Continuously rated.
  • Stainless steel fixings.
  • Unit can be mounted using external lugs or internal BESA compatible fixing positions.
  • Duplicate cable terminations (in & out for daisy-chain installations).
  • Tropicalisation available on request.
  • Available with custom tone configurations and frequencies.
  • Stage programmable version available:
    • 45 alarm tones
    • 4 remotely selectable stages
    • Any tone can be assigned to any stage
    • User configurable continuous frequency tone

 

Specification

Maximum output: 112dB(A) @ 1 metre [103dB(A) @ 10ft/3m]
Nominal output: 105dB(A) @ 1m +/- 3dB – Tone 2 [96dB(A) @ 10ft/3m]
No. of tones: 32 (UKOOA / PFEER compliant)
No. of stages: 3
Volume control: Max. 105dB(A);
Min. 96dB(A) – Tone 2
Effective range: 60m/197ft @ 1KHz
Voltages DC: 24V dc (10-30V dc);
48V dc (35-60V dc);
110V dc (72-130V dc)
[24V dc units can use 24V ac for single stage apps.]
Voltages AC: 24V ac; 115V ac; 230V ac
Stage switching: Negative
Positive switching option available
Reverse polarity stage switching on DC units.
Ingress protection: IP66
Enclosure material: High impact UL94 V0 & 5VA FR ABS
Enclosure colour: Red (RAL3000), Grey (RAL7038)
Cable entries: 2 x M20 clearance gland entries in side & back
Terminals: 0.5 to 1.5mm² cables.
Operating temp: -25 to +55°C [-13° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 0.75kg/1.65Ibs AC:1.00kg/2.2Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.

 

Current Consumption

Version: Voltage: Current:
24V dc 10-30V dc 25mA*
48V dc 35-60V dc 50mA*
110V dc 72-130V dc 27mA
24V ac 50/60Hz +/-10% 40mA
115V ac 50/60Hz +/-10% 20mA
230V ac 50/60Hz +/-10% 15mA
* current at nominal voltage on Tone 2

 

Please refer to data sheet for more information

Data Sheet - A105N Alarm Sounder

Manual - A105N Alarm Sounder

Hover Box Element

Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.