OxySteam

Steam Boiler Water Degassing with OXYTRANS TR
To generate steam, water is heated in a steam boiler, but the oxygen present can cause harmful corrosion, necessitating thermal degassing. The Centec OxySteam has been developed as a system for regulating the steam used for degassing continuously. The Centec OXYTRANS TR can be used to monitor the O2 content of the exhaust vapor and to precisely control the valve for discharging the steam. The remaining opening time of the valve is a measure of the steam savings. Steam losses can be reduced by up to 95 %.

Category:
Send Enquiry

Description

Technical Description – OxySteam

The Centec OxySteam has been developed as a system for regulating the steam used for degassing continuously, which can reduce steam losses by up to 95 %. The process monitors the O2 content of the exhaust vapor. The exhaust valve is then controlled via a programmable logic controller (PLC) to only discharge steam when necessary for the effective and efficient control of the degassing process. To reduce the steam loss, vapor condensers are sometimes used alternative, normally within the fresh make-up feed water used as the cooling medium. However this only works while there is a requirement for additional cold make-up water. Since this only occurs intermittently, the vapor cannot be condensed or used a lot of the time.

 

A Closer Look

  • Optical technology; no electrolyte and membrane changes
  • Short response time and excellent long-term stability
  • Ideally suited for high temperature applications
Assume a boiler with a capacity of 10 t/h and an assumed steam loss of 0.3 % results in a steam loss of 263 t per year (365 days x 24 h = 8,760 h). Of this, 250 t can be saved. If the tonne of steam is set at 40 AUD, the saving amounts to 10.000 AUD/year with a sustainable and quick return of investment.
Centec OxySteam

The Specs at a Glance

Liquid Phase
Measuring Ranges
I) 1 ppb – 2 ppm II) 30 ppb – 35 ppm
Accuracies
I) ± 1 ppb II) ± 30 ppb
Gas Phase
Measuring Ranges
I) 0 – 4.2 % O2 II) 0 – 50 % O2
Accuracies
I) ± 0.002 % O2 II) ± 0.03 % O2
Response Time
t90 ≤ 10 s
Pressure of Operation
max. 12 bar
Temperature of Operation
– 5 – + 55 °C (Pt100)
optional: max. + 98 °C
(+ 98 – 120 °C: less accuracy)
Material
1.4404/AISI 316L, silicone (FDA), PTFE (FDA)
Input
1 x analog (4 – 20 mA) & 3 x digital (24 VDC)
Output
2 x analog (4 – 20 mA) & 3 x digital (24 VDC) optional: PROFIBUS DP & PROFINET
Enclosure Rating
IP65
Power Supply
24 VDC

Data Sheet – OxySteam

Food and Beverage

Hover Box Element