Description
Technical Description â TurbiGuard AD 40
In-line Turbidity Monitor for Medium to High Turbidity
The TurbiGuard AD 40 is used to measure medium to high turbidity. A single device covers the corresponding applications. The TurbiGuard AD 40 is calibrated with Formazin over the entire linearised measuring range. Simple configuration and communication via one of the available interfaces, from 4…20 mA current interfaces to bus systems, guarantee simple application and system integration. The TurbiGuard AD 40 comes in a new, fresh design with an integrated colour touchscreen display. This makes the TurbiGuard AD 40 easy to identify in the system. The status is displayed directly in the device at the measuring point. The security of the data on the new interfaces is guaranteed.
A Closer Look
A universally applicable device with a large measuring range, simple installation in a standard housing without tools, integrated measured value display and
maximum flexibility in configuration and communication -this is what modern process measuring devices look like today.
Precision Turbidity Measurement
Enables real-time monitoring of turbidity in a wide range of processes. Measures turbidity and detects any deviations early, helping to avoid off-spec batches.
The TurbiGuard AD 40 helps to ensure the quality of the end product.
Typical Applications Include:
- Turbidity measurement or monitoring in beverages such as beer, fruit juices
- Control of centrifuges, separators, whirlpools
- Filter performance and filter breakthrough monitoring
- Determination of the solids concentration
- Yeast propagation and dosing
Specs at a Glance
| Measuring principal | Absorption |
| Wavelength | 870nm |
| Measuring range | 0..2000 EBC (0âŚ8000 NTU) |
| Resolution | 0.5 EBC/2 NTU |
| Accuracy | 0 â 1000 EBC: +/- 3%, min. +/- 3 EBC 1000 â 2000 EBC: +/- 5% * |
| Repeatibility | +/- 0.25%; min. +/-0.5 EBC |
| Response time | < 0.3 s at 0 Seconds Integration time (Step response Ă limit value switch) |
| Path length | 10 mm |
| Medium temperature | -10 … +100 °C -10 ⌠+85°C at ambient temperature 55°C -10 ⌠+75°C at ambient temperature 60°C |
| Cleaning surroundings | CIP/SIP- compatible up to 120 °C @2h -10 ⌠+50 °C 0 … 100 % relative humidity |
| Medium pressure | Max. 1 MPa (10 bar) @100 °C |
| Pipe connections | Inline VARINLINEÂŽ – housing or compatible DN 40 ⌠DN 150, 1 1/2â… 6â |
| Operating voltage | 24 VDC Âą 10 % (Interface PoE according to standard) |
| Warm up time | < 3 min |
| Power consumption | Max. 3 W |
| Protection class | IP 66 |
| Dimensions | Ă 100.5 x 137 mm |
| Material | Housing: Stainless steel 1.4301 / AISI 304 Sensor head material: Stainless steel 1.4404 / AISI 316L Window material: Sapphire Touchscreen: Soda-Lime tempering glas |
| Weight | 1.5kg |
| Display | Display: 2.4â with Touchscreen Resolution: 320 x 240 Pixel |
| Interfaces | |
| LT (Standard) | 1 Current output 0/4 ⌠20 mA, max. 700 Ohm, 1 digital input, 2 digital outputs |
| IO | 6 configurable inputs/outputs: – Max. 2 digital inputs: 5 ⌠28 VDC – Max. 4 digital outputs: High-Side Switch max. 20 mA – Max. 4 current outputs: 0/4 ⌠20 mA, max. 700 Ohm – Modbus RTU |
| PoE | Ethernet LAN connection with Power over Ethernet: – Ethernet according to 10/100BaseT – POE according to 802.3af, Class 0 – Sigrist Web interface |
| Profibus | Profibus DP-V1 Slave |
| Profinet | Profinet IO, Conformity class B |
| * in reference to factory standard |
Available upon request.
Sigrist Communication Software
Software for Sigrist devices of the Edge generation.