Menu Search

Enquire Now

Give us a call for an immediate response today on any technical information, products or solutions.
Or alternatively please take a moment to fill out this form.

PHONE

Head Office:
+61 (02) 9620 8700

Melbourne Office:
+61 (03) 9589 3256


Dairy 2

Milk Carbonation

Search filters:
Centec

Centec designs and manufactures automated process skids for efficient and reliable production of pasteurized, ESL and UHT milk. Units for milk standardization, systems for concentration and deaeration, flash pasteurizers and blending skids, carbonating and CIP units – Centec equipment is largely used for manufacturing of cream, butter and many fermented dairy products (e.g. yogurt, kefir, laban). Centec technology includes a range of high precision process sensors for accurately measuring critical product properties such as milk fat content, O2 and CO2. The largest dairy groups in the world are among our key customers

Successfully Applied by Various Dairy Groups

Addition of carbon dioxide (CO2) is an important method of improving the quality of cheese milk. CO2 occurs naturally in milk, but most of it is lost in the course of cheese making. Adding CO2 by artificial means lowers the pH of the milk. This results in shorter coagulation time. The effect can be utilised to obtain the same coagulation time with a smaller amount of rennet. 

  • Reliable Process Control Based on Proven CARBOTEC Technology
  • Easy Operation and Maintenance
  • Outstanding Price-Performance-Ratio

 

 

Technical Data

CARBONATOR

Capacity

10 - 2.000 hl/h

Range of CO2

0 - 10 g/l or

0 - 5 vol.%

Control Accuracy

± 0,05 g/l or

± 0,025 vol.%

Pressure of Operation

1 - 10 bar

Temperature of Operation

2 - 50 °C

Temperature of CIP

up to 85 °C

Material

1.4301/1.4404

AISI 304/316L

PLC

SIMATIC S7

Options

in-line measurement of CO2

nitrogenation

blending


 

 

Technical Data

CARBOTEC TR-PT

CARBOTEC NIR

 

Measuring Range

 

0 - 10 g/l

 

0 - 10 g/l

Accuracy

± 0,05 g/l

± 0,1 g/l

Repeatability

± 0,01 g/l

± 0,02 g/l

Response Time

≤ 20 s

≤ 3 s

Pressure of Operation

max. 10 bar

max. 10 bar

Temperature of Operation

- 10 - + 100 °C

- 10 - + 90 °C

Temperature Compensation

Pt100

Pt100

Material

1.4404/AISI 316L,

EPDM (FDA), PTFE (FDA)

1.4404/AISI 316L,

sapphire glass,

EPDM (FDA), PTFE (FDA)

Connections

compatible to Varivent©

Inline-Housings DN65 - DN150;

others on request

compatible to Varivent©

Inline-Housings DN65 - DN150;

others on request

Input

6 x digital (24 VDC)

6 x digital (24 VDC)

Output

3 x digital (24 VDC) &

2 x analog (4 - 20 mA)

3 x digital (24 VDC) &

2 x analog (4 - 20 mA)

Profibus DP

option

option

Enclosure Rating

IP65

IP65

Power Supply

24 VDC

24 VDC

 

CARBOTEC


 

Request More Information


Contact ProDetec, call us on +61 2 9620 8700