Sigrist SIREL Ex

SIREL Ex

The Sirel Ex is the hazardous area Operator Interface for the ColorPlus Ex (colour and UV) and DualScat Ex (turbidity). The Sirel Ex has simple installation specifically for mounting in an Ex-zone with user controls and display. The display of the unit is visible through a safety window at any time.

Sigrist SICON

SICON

The control unit SICON uses state-of-the-art touch screen technology with colour display. It allows simple operation using logical menu guidance. The user can select how results are displayed, either as plain values, graphs or historical data, including the indication of system and alarm status.

The control unit SICON offers all possibilities of full system integration using various interface options. A SD card is standard and can be used for data logging with almost unlimited storage capacity.

The SICON is available as a control unit for a single instrument, or the SICON M Control Unit which allows simple operation of several instruments up to a maximum of 8 measuring channels.

Teledyne Oldham Simtronics DG-TX7 Catalytic Combustible Gas Detector

DG-TX7 Catalytic Combustible Gas Detector

The MultiXplo DG-TX7 intelligent catalytic sensor based flammable gas detector used to detect Hydrogen H2 and other HC gases. The device has been designed for ease of installation, operation and maintenance in testing environments. 

Teledyne Oldham Simtronics Multi TOX and Oxygen Detector

Multi TOX and Oxygen Detector

The Multi Tox DG7 series is an intelligent gas detector employing an array of sensor types. The DG7 Series is used for Toxic gases or Oxygen monitoring. The device has been designed for ease of operation and maintenance. 

Teledyne Oldham Simtronics GD1 H2S Laser Diode Open Path Detector

GD1 H2S Laser Diode Open Path Detector

The Simtronics GD1 sets a new standard for toxic gas detection. Using a laser diode technology, the GD1 delivers enhanced coverage and fail-safe detection. The performance improvement marks a genuine step change for safety systems and life cycle cost savings. 

The GD1 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from offshore production facilities to wastewater treatment plants. 

At the heart of the detector is a laser diode that eliminates environmental effects from sun, rain and fog. The laser scans single absorption lines where there is no interference from other gases. 

Unlike traditional methods for detecting H2S (MOS or EC cell) the GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk. 

The complete optomechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs. 

Supplied with worldwide hazardous area approvals. Sui table for use in systems with SIL 2 requirement. 

Teledyne Oldham Simtronics DF-TV7 IR3 Flame Detector (SIL3)

DF-TV7 IR3 Flame Detector (SIL3)

The MultiFlame DF-TV7–T is a multi-spectrum infrared flame detector using three wavelengths. The MultiFlame DF-TV7-T responds to hydrocarbon fires and is the right choice for operation in dirty environments or for detection of smoky fires.  

Teledyne Oldham Simtronics DF-TV7 UV2IR Flame Detector (SIL2)

DF-TV7 UV2IR Flame Detector (SIL2)

The Simtronics DF-TV7 is a combined ultraviolet / infrared flame detector offering excellent flame detection whilst maintaining outstanding false alarm immunity.  The UV/2IR Multi Flame DF-TV7  is designed to respond to unwanted hydrocarbon fires, whilst maintaining a high degree of false alarm immunity. The DF-TV7 flame detector uses combined ultraviolet/infrared (UV-2IR) optical technology that provides industry-leading immunity to false alarms based on the two IR channel design. 

The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs. 

All Multi Flame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU wireless handheld unit that is approved for use in hazardous areas. The TLU can also be used for wireless testing of the optical and output circuits. The TLU can also be used for wireless testing of the optical and output circuits. 

Sintrol DumoPro Continuous Ambient Air Dust Monitor

DumoPro Continuous Ambient Air Dust Monitor

New and improved continuous ambient air dust monitor for industrial environments.

Low maintenance real-time 24/7 trend monitoring in key areas to detect and alarm of dust events with fast response to changes in process conditions, the DumoPro utilises Sintrol’s proven measuring technology

Riken Keiki Co OHC 800

OHC 800

Explosion Proof Calorimeter

The OHC-800 is an explosion-proof calorimeter. According to measured calorific values, 4 – 20 mA signals and digital signals are output. The calorimeter is used for the purposes of calorific value recording and device control by connecting it to a recorder or a programmable controller. The calorimeter has three contact outputs, and these are activated by malfunction etc. of the device.

Sintrol S100 Broken Bag Detector

S100 Broken Bag Detector

The S100 series is designed to measure the concentration of dust particles inside a pipe or duct. This makes it an ideal solution for detecting filter leaks or failures in cyclonic separation in various industrial applications.

The operating principle is based on inductive electrification technology, where particles interacting with an isolated probe induce a signal that is transmitted to the monitoring system. The normal dust level is determined during commissioning, and the signal generated by the sensor is then scaled in proportion to this baseline level when the dust level fluctuates.

Sintrol S201 Dust Guard

S201 Dust Guard

With two independent alarm relays, Sintrol’s S201 allows the end user to identify bag leaks and deterioration of filters. Using our electric induction measurement principle, the dust monitor can be easily set up within 30 minutes of installation and gives plant operators quick notification of breaches in the filtration system.

Sintrol dust monitor allows end users to manually adjust alert and alarm level signals to tailor to their end needs. Different probe lengths and coatings give flexibility to meet a variety of applications.

Sintrol S203 Trend Monitor

S203 Trend Monitor

Continuous trend monitor that gives plant operators to see the performance of the filtration systems and ducts over a period of time. Perfect for installation after any filtration system or in common line channels leading into the emissions points of a plant.

State of the art Inductive Electrification principle minimises the need for maintenance on the dust monitor and provides an accurate trend for end users. 4-20mA output combined with an easy to use auto-setup feature that takes less than 30 minutes from installation makes the device both convenient and reliable.

Sintrol S303 Process Dust Monitor

S303 Process Dust Monitor

Continuous trend monitor that gives plant operators to see the performance of the filtration systems and ducts over a period of time. Perfect for installation after any filtration system or in common line channels leading into the emissions points of a plant.

State of the art Inductive Electrification principle minimises the need for maintenance on the dust monitor and provides an accurate trend for end users. 4-20mA output combined with an easy to use auto-setup feature that takes less than 30 minutes from installation makes the device both convenient and reliable.

Sintrol S304 Emissions Monitor

S304 Emissions Monitor

For applications requiring absolute value measurements of dust concentrations, the S304 can be calibrated to give the user a mg/m3 output. Once calibrated, this dust monitor helps plant operators know exactly how much dust is passing through the stack or outlet duct of their plant.

The S304 is additionally equipped with a 4-20 mA signal and two independent alarm relays that can be used to further optimised process conditions in the plant.

Utilising our unique Inductive Electrification principle, the S304 brings the reliability the government requires and combines it with the convenience plant operators expect from a particulate measurement device. With minimal maintenance required, this is an optimal solution for plant operators needing to measure stack dust emissions for government control.

Sintrol DustLog8

DustLog8

DustLog 8 is the premier central management solution for dust measurement equipment.

It gives plant operators full control over the network of dust monitors with efficient parameterising, reporting and networking functions on an easy to use interface. By unifying all of Sintrol’s latest technology into one management tool, DustLog 8 brings not only greater convenience and usability, but also improves plant efficiency, network management and worker safety for the end user.

The DustLog 8 PC software can be connected via a network router to the dust monitors. RS485, Modbus and RF are supported

Sintrol Wireless Solutions

Wireless Solutions

In addition to our measurement devices, Sintrol’s Wireless Monitoring System makes it easier to connect, track, manage and control a network of dust monitors. Using any combination of Sintrol’s dust monitors, the entire system can be integrated and set up via our RF network and managed with our DustLog 8 software.