Filter products Showing 209 - 224 of 225 results
Filter
Spectrex SafEye Quasar 900 Open Path Gas Detector

SafEye Quasar 900 Open Path Gas Detector

The New SafEye Quasar 900 is an open path detection system which provides continuous monitoring for combustible hydrocarbon gases. It employs “spectral fingerprint” analysis of the atmosphere using the Differential Optical Absorption Spectroscopy (DOAS) technique. The Quasar 900 consists of a Xenon Flash infrared transmitter and infrared receiver, separated over a line of sight from (7m) up to (200m) in extremely harsh environments where dust, fog, rain, snow or vibration can cause a high reduction of signal.  

Spectrex SafEye Quasar 950 H2S Open Path Gas Detector

SafEye Quasar 950 H2S Open Path Gas Detector

The Quasar 950 Open Path Toxic Gas Detector Series offers proven fast and reliable detection of toxic H2S gases and vapours over a line of sight of up to(60m) and are built for continued operation under extreme environmental conditions. The Quasar 950 can be tailored to protect your personnel and high-risk installation. Reliability is key and is assured with SIL2. 

All Quasar 950 detectors incorporate heated windows to minimize any effects from condensation, icing, snow and are totally immune to interference from sunlight or any other sources of radiation such as flare stacks, arc welding or lightning. A range of outputs are available including mA, HART, Modbus RS485 to suit all control systems. 

Spectrex SafEye Quasar 960 NH3 Open Path Gas Detector

SafEye Quasar 960 NH3 Open Path Gas Detector

The latest SafEye Quasar open path UV detection technology includes the 960 series. The Quasar 960 models detect toxic Ammonia gas, with path lengths of up to (60m). The Quasar 960 model can be tailored to protect your personnel and high-risk installation. Reliability is key and is assured with SIL2. 

All Quasar 960 detectors incorporate heated windows to minimise any effects from condensation, icing, snow and are totally immune to interference from sunlight or any other sources of radiation such as flare stacks, arc welding or lightning. A range of outputs are available including 0-20mA, HART, Modbus RS485 to suit all control systems. 

Stuvex TES01 Truck Earthing System

TES01 Truck Earthing System

Loading and unloading of tanker trucks with liquids or powders can generate static electricity that could cause sparks discharging. The Stuvex TES01-V2 earthing verification system has been designed to detect a low electrical resistance between the clamp jaws that are attached to the truck’s earthing point. 

Stuvex S604 and S804 Static Discharge Systems

S604 and S804 Static Discharge Systems

An electrostatic charge can be generated while handling conductive liquids or powders.  A resistive system (S604) recognises the low conductive resistance of the object and of fixed installations. It is meant for general use with barrels, carts, metal objects. Uncontrolled electrostatic discharge when filling or unloading big bags is a frequent source of ignition. The earthing Control System (S804) recognises the conductivity of an FIBC (Big Bag) type C.

Stuvex StuVent Explosion Venting

StuVent Explosion Venting

The oldest and most frequently used explosion protection technique is explosion venting. That means that weak points are deliberately introduced in the equipment in a controlled way. In case of an explosion, these weak points will open, and the explosion pressure is released. It is not easy to calculate and correctly position the right venting surface. 

Stuvex RSV Fast Shutting Gate Valve

RSV Fast Shutting Gate Valve

RSV fast shutting gate valves prevent propagation of dust explosions by blocking the shock wave and flame. RSV fast shutting gate valves are active valves closing in a matter of milliseconds when triggered by a spark or explosion detector. 

Stuvex Flame Catcher

Flame Catcher

In case of an explosion, the Flame Catcher prevents flames from propagating beyond the Flame Catcher.

Stuvex NOVEX Passive Explosion Isolation Flap Valve

NOVEX Passive Explosion Isolation Flap Valve

The NOVEX series is a protective system consists of passive non-return flap valves for the explosion isolation of combustible dust. The main application for the NOVEX valves is for explosion isolation on pipelines at inlet of dedusting filters operating under vacuum and protected by autonomous explosion vent panels. 

Stuvex Flash Explosion Suppression System

Flash Explosion Suppression System

Based on the Flash explosion suppression system and operating in a similar manner, Flash chemical barriers are capable of detection an explosion in an early stage by means of pressure or flame detectors. 

Stuvex VENTEX Passive Isolation Valve

VENTEX Passive Isolation Valve

Ventex explosion isolation valves prevent propagation of dust explosions by blocking the shock wave and flame front. Ventex valves are passive valves meaning they will close without requiring any external input. 

Union Instruments INCA 1000 Series

INCA 1000 Series

Modular measuring device for indoor installation without a gas cooler, max. 2 sampling points.

The devices of the INCA1000 series comprise multi-component gas analysers which are fixed engineered for use in a defined application. The sample must be condensate-free (see data sheet). The devices are designed for indoor installation and available in different versions

Union Instruments INCA 3000 Series

INCA 3000 Series

Modular measuring device for indoor installation without a gas cooler, max. 6 sampling points

The devices of the INCA3000 series are multi-component gas analysers for analysis of condensate-free sample gas. The devices of this series are specially designed for indoor installation and are available in different versions.

Union Instruments INCA 4000 Series

INCA 4000 Series

Modular measuring device for indoor installation with a gas cooler, max. 10 sampling points

The devices of the INCA4000 series are self-priming multi-component gas analysers for analysis of condensate-containing sample gas; exception: the INCA4004 version is used for condensate-free sample gas The devices of this series are specially designed for indoor installation and are available in different versions.

Union Instruments INCA 5000 Series

INCA 5000 Series

Modular measuring device for outdoor installation without a gas cooler, max. 10 sampling points

The devices of the INCA5000 series are multi-component gas analysers for analysis of condensate-free sample gas. The devices of this series are specially designed for outdoor installation and are available in different versions.

Union Instruments INCA 6000 Series

INCA 6000 Series

Modular measuring device for outdoor installation with a gas cooler, max. 10 sampling points

The devices of the INCA6000 series are multi-component gas analysers for measurement of condensate-containing sample gas. The devices of this series are specially designed for outdoor installation and are available in different versions.