MX16 Single Channel Controller

The MX 16 is a compact digital or analog controller, one input, low-profile controller that continuously monitors gas detection and more generally to the processing of any 4-20 mA, on/off or compatible digital signal.

Description

Technical Description – MX16 Single Channel Controller

The MX 16 is a compact digital or analog controller, one input, low-profile controller that continuously monitors gas detection and more generally to the processing of any 4-20 mA, on/off or compatible digital signal. The MX 16 instantly handles the measurements of detectors. As soon as the measurements reach the configured thresholds, the internal buzzer and the LED indicators go on. At the same time, the corresponding relays are activated to drive the additional actions programmed by the user.

The system primarily comprises:

  • MX 16 controller
  • One analog or digital detector

A Closer Look

The MX 16 is a compact digital or analog controller, one input, low-profile controller that continuously monitors gas detection, like:

  • O₂
  • CO₂
  • CH₄
  • H₂
  • LPG

Specially designed for applications in laboratory, storage, small boiler room, and breweries or battery charging rooms, the MX 16 measuring unit prevents the risks of explosion linked to the presence of toxic, anoxic and explosive gases in the ambient air. Small size, ease of installation and use are the main strengths of the plant. Used with the OLCT 10N O₂ and CO₂ digital sensor series or any other O₂, CO₂, CH₄, GPL and H₂ analog sensor, the MX 16 guarantees you a solution that complies with International Standards.

NEW! 

Available in Easy Duo version, a new controller + detector + cable* offer.

This offer applies to versions:

  • MX 16 + OLCT 10N O₂
  • MX 16 + OLCT 10N CO₂
  • Simplified configuration (no software)
  • Available in 4-20mA version.
  • Easy and ready to use.

Features & benefits

Industry standard signal format

  • Accepts 4-20 mA inputs from Teledyne Gas Detection equipment
  • Accepts 2-and 3-wire 4-20 mA signal formats
  • Accepts 4-20 mA inputs from 3rdParty devices * Consult ProDetec for more details and possible limitations
  • Individual signal lines for each gas detector provides highest reliability (fault detection)
  • Long signal transmission distances
  • Limited to O2. CO2, CH4, LPG and, H2

Applications

  • MRI (with dedicated CTX300 O2 years, He free)
  • Breweries
  • Boiler rooms
  • Laboratories
  • Fuel Storage areas
  • Gas cylinder storage area
  • Back-up Battery rooms

The Specs at a Glance

The MX 16 controller is available in 2 versions:

  • 1 line for digital detector:

– OLCT10N O2 (0-30% Vol.)

– OLCT10N CO2 (0-5;00% Vol.)

  • 1 line for 4-20mA analog detector:

– O2 (0-30% Vol)

– CO2 (0-5.00% Vol.)

– CH4 (0-100% LEL)

– LPG (0-100% LEL)

– H2 (0-100% LEL)

  • Analog and digital controller
  • NEW! Discover the preconfigured pack with cable: Easy Duo
  • Analog and digital controller
  • Low cost and Easy to install
  • 1 measurement line / up to 1 detectors
  • Integrated relays
  • RS-485 Signal Output (optional)Fully scalable

Data Sheet – MX16 Single Channel Controller

Easy Duo

Hover Box Element