SpyGlass SG50-F-IR3-H2-V

The SpyGlass SG50-F-IR3-H2-V will detect hydrogen fires and explosions extremely fast, thus allowing preventative action to be initiated even more rapidly and minimizing the consequences!

Integral HD quality video, with event recording, on top of the proven, superior capabilities of Triple IR (IR3) flame detection, provides a very powerful safety tool to protect personnel, plants, and processes.

The SpyGlass SG50-F-IR3-H2-V flame detector provides ultra-fast response, high performance, and reliable detection of hydrogen fires. It operates in all weather and light conditions with the highest immunity to false alarms.

Description

Technical Description – SpyGlass SG50-F-IR3-H2-V Triple IR Flame Detector

The SpyGlass SG50-F-IR3-H2-V is the next generation of the IR3. It is being introduced to further enhance the protection and safety for these high risk and high value industries.

​The SG50-F-IR3-H2-V will detect hydrogen fires and explosions extremely fast, thus allowing preventative action to be initiated even more rapidly and minimizing the consequences!

Integral HD quality video, with event recording, on top of the proven, superior capabilities of Triple IR (IR3) flame detection, provides a very powerful safety tool to protect personnel, plants, and processes.

​​The SG50-F-IR3-H2-V flame detector provides ultra-fast response, high performance, and reliable detection of hydrogen fires. It operates in all weather and light conditions with the highest immunity to false alarms.

​​In addition, the detector’s high-definition (HD) video output provides visualization of hydrogen flames that are invisible to the human eye. This allows the rescue team to be aware of the exact situation and location of invisible hydrogen flames before entering the hazardous area. The detector automatically records video of any fire event (1 minute pre- and up to 3 minutes post alarm initiation). These features, along with the built-in event logger, provide additional means to study the cause and development of fire events for “lessons learned” reviews

A closer look

The unmatched detection times and distances are:

  • Detection within 40 milliseconds of fireballs or explosions
  • 5s for 32″ (0.8m) hydrogen fire at 0–66 ft. (0–20m)
  • 4s for 32″ (0.8m) hydrogen fire at 66–100 ft. (20–30m)
  • High immunity to false alarm
  • Ultra-fast detection mode detection within 40 milliseconds for Hydrogen fireballs or explosions Hydrogen flame detection
  • High sensitivity – up to 100 ft. (30m)
  • HD video output with Automatic HD video recording of fire events. Visualization of hydrogen flames that are invisible to the human eye.
  • Data/Event logger – alarms, faults and other relevant events are logged to non-volatile memory
  • Ethernet communication – in addition to the standard methods, such as Relays, 4-20mA and Modbus
  • Built-in-Test (BIT) – Automatic and manual internal self-test of window cleanliness and the overall operation of the detector
  • Window heater to avoid condensation and icing

 

The Specs at a Glance

Technology Triple IR Flame Detector for Energy Transition
Fire type Hydrogen fires
Video Functionality
HD Video Near IR filtered HD, as standard. Colour HD option (X2 available on request)
Recording of alarm events 1 minute pre-event and up to 3 minutes post-event
System integration protocol ONVIF (Open Network Video Interface Forum) Profile S
 

Detection time and distance

40ms for fast fire burst or explosion
1.5s for 32″ (0.8m) hydrogen fire at 0–66 ft. (0–20m)
Sensitivity Range 5 ranges, Extreme, High, Medium, Low, Very Low
Field of view (IR detection) 90° Horizontal, 75° Vertical
Output signal
 

Standard

3 wire and 4 wire (isolated) configurations (sink and source) 4-20Ma or 0-22ma (configurable by the user)
Hart protocol 7th edition (option)
Relays SPST volt-free contacts rated 2A at 30 VDC 3 relays: Alarm & Auxiliary – normally open; Fault – normally closed
Visual Tri-colour LED (Green, Yellow, Red)
Digital (for video) IP network IEEE 802.3 100Base-T
Composite video NTSC or PAL
Modbus RTU compatible on RS-485
Electrical
Power supply 24 VDC nominal (18-32 VDC)
Power consumption Standby: 180mA Maximum: 300mA (including window heater)
 

Connection

2x cable and conduit entries 3/4″ NPT(F) or M25x1.5
12-20AWG (2.5–0.35mm2)
Shielded cable recommended
Environmental
Temperature Range Operating: -67°F to +185°F (-55°C to +85°C)
Storage: -67°F to +185°F (-55°C to +85°C)
Option Stainless steel weather cover, model FLS-WCO-S02
Humidity Up to 99% (RH), non-condensing
Ingress IP66 & 68 (2m, 24hr); NEMA 4X & 6P
Mechanical
Size 7.87 x 5.12 x 5.12″ (200x130x130mm)
Weight Detector (Stainless Steel 316): 9.8 lbs. (4.4 kg)
Tilt mount (Stainless Steel 316): 5.4 lbs. (2.4 kg)

Data Sheet – SG50-F-IR3-H2-V

IECEx Certificate of Conformity

Hover Box Element