- Industries
- Refining - Downstream
Refining – Downstream
The principal hazards at refineries are fire and explosion. Refineries process a multitude of products with low flash points. Although systems and operating practices are designed to prevent such catastrophes, they can occur. Constant monitoring is therefore required. Safeguards include Fire and Gas warning systems, emergency procedures, and permit systems for any kind of hot or other potentially dangerous work. These requirements must be understood and followed by all workers.
Applications
ProDetec has access the the worlds best gas detectors for a wide range of industries. Whether the need is for a single application or multiple sites and areas, our durable gas monitoring solutions meet your unique industrial needs. We offer a broad range of gas detectors and controllers to satisfy international certification standards such as SIL (Safety Integrity Level), Marine and IECEx.
GD10P Hydrocarbon Infra Red Point Gas Detector
The Simtronics GD10P detector is the benchmark for combustible gas detection for offshore oil and gas installations. It has set the standard for gas detectors in the areas of safety, stability and low maintenance both onshore & offshore.
The GD10P has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations.
These IR gas detectors differ from all other models, because they utilise silicon based solid-state IR sources. The complete opto-mechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.
We offer the longest combined detector and IR source warranty on the market.
For retrofit applications, a bridge interface is available allowing the detector to be connected directly to catalytic systems, using cabling and control modules.
GD10PE High Sensitivity Gas Detector
The GD10PE is designed for critical applications involving large volumes of air with high velocity. In places where you need fast reliable detection of low gas concentrations, GD10PE is in a class of its own.
The versatile GD10PE is suitable for monitoring, among others, the HVAC air intakes of living quarters, temporary refuges and local equipment rooms. In addition, the ventilation air and combustion air intakes of gas turbines can be monitored along with the ventilation air extract duct, the only location where you can guarantee to detect a gas leak on a turbine package. With a measuring range of 0-20%LEL the GD10PE is 5 times more sensitive than standard point detectors. This, and a response time in the region of 1 second should cover even the most demanding requirements. It can also tolerate continuous operation at 85°C inside the duct.
iTrans2 Gas Detector
The iTrans2 infrared gas detector employs an intelligent electronics platform to provide one or two points of detection from a single head for maximum flexibility, superior performance, and lower installation costs. With the optional HART Communication Protocol, the iTrans2 offers remote diagnostics, set-up, or calibration by superimposing a high-frequency current across the industry standard 4-20mA analog line.
OLCT100 Gas Detector
The high-performance OLCT 100-XP-MS range of flammable gas detectors from Teledyne Gas and Flame Detection now incorporates cutting-edge MEMS (Micro-ElectroMechanical Systems) sensor technology. Delivering the market’s most accurate readings for over 14 of the most common combustible gases and gas mixes — including hydrogen, methane, propane and butane — MEMS technology adds to the capabilities provided by conventional sensors. Users also enjoy notable advantages regarding ‘poison’ immunity and operating life, particularly in environments that sometimes prove challenging for catalytic sensors.
DG-TX7 Catalytic Combustible Gas Detector
The MultiXplo DG-TX7 intelligent catalytic sensor based flammable gas detector used to detect Hydrogen H2 and other HC gases. The device has been designed for ease of installation, operation and maintenance in testing environments.
Multi TOX and Oxygen Detector
The Multi Tox DG7 series is an intelligent gas detector employing an array of sensor types. The DG7 Series is used for Toxic gases or Oxygen monitoring. The device has been designed for ease of operation and maintenance.
LaserGas™ III Open Path
LaserGas™ III Open Path gas detector is specifically designed for continuous monitoring in hazardous areas.
Based on our third generation LaserGas™ Technology, the entire instrument is built into compact flameproof enclosures which makes it ideal for zone 1 locations.
The LaserGas™ III OP consists of a transmitter and receiver unit that is mounted facing each other at distances up to 100 meters. The laser light is sent from the transmitter to the receiver and any changes in gas concentration along the optical path from the transmitter to the receiver are detected in real-time.
SpyGlass Open Path Combustible Gas Detector
The Spyglass system detects hydrocarbon gases by analysing the absorption of radiation caused by gases in the atmosphere and comparing it to background atmospheric absorption. This is accomplished between a pair of units: a Flash Source and a Detector that can monitor a distance of up to 200 metres.
Spyglass Gas Detectors are robustly designed and can handle the toughest environments: 316L stainless steel housings that meet IP66/IP68 and NEMA 250 6P egress standards; circuit boards epoxy coated for protection; MIL-C-810C testing for humidity, salt, fog, vibration, mechanical shock and temperature extremes; and SIL-2 approval per IEC61508 is a final statement in reliability.
SafEye Quasar 900 Open Path Gas Detector
The New SafEye Quasar 900 is an open path detection system which provides continuous monitoring for combustible hydrocarbon gases. It employs “spectral fingerprint” analysis of the atmosphere using the Differential Optical Absorption Spectroscopy (DOAS) technique. The Quasar 900 consists of a Xenon Flash infrared transmitter and infrared receiver, separated over a line of sight from (7m) up to (200m) in extremely harsh environments where dust, fog, rain, snow or vibration can cause a high reduction of signal.
GD1 H2S Laser Diode Open Path Detector
The Simtronics GD1 sets a new standard for toxic gas detection. Using a laser diode technology, the GD1 delivers enhanced coverage and fail-safe detection. The performance improvement marks a genuine step change for safety systems and life cycle cost savings.
The GD1 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from offshore production facilities to wastewater treatment plants.
At the heart of the detector is a laser diode that eliminates environmental effects from sun, rain and fog. The laser scans single absorption lines where there is no interference from other gases.
Unlike traditional methods for detecting H2S (MOS or EC cell) the GD1 needs no recalibration and can replace multiple standard detectors to cover the same risk.
The complete optomechanical design and construction is so stable that an ultra-fast speed of response can be achieved whilst providing unparalleled service life and detector stability, thus saving on maintenance and service costs.
Supplied with worldwide hazardous area approvals. Sui table for use in systems with SIL 2 requirement.
SafEye Quasar 950 H2S Open Path Gas Detector
The Quasar 950 Open Path Toxic Gas Detector Series offers proven fast and reliable detection of toxic H2S gases and vapours over a line of sight of up to(60m) and are built for continued operation under extreme environmental conditions. The Quasar 950 can be tailored to protect your personnel and high-risk installation. Reliability is key and is assured with SIL2.
All Quasar 950 detectors incorporate heated windows to minimize any effects from condensation, icing, snow and are totally immune to interference from sunlight or any other sources of radiation such as flare stacks, arc welding or lightning. A range of outputs are available including mA, HART, Modbus RS485 to suit all control systems.
MX32 Multi Channel Controller
The new MX 32, a controller that takes analog & digital inputs and covers all needs for a wide variety of applications. The MX 32 is a compact, low-profile controller that continuously monitors gas detection and more generally any 4-20 mA, MODBUS RS485 signal from compatible detectors.
MX43 SIL-1 Certified Gas Detection Controller
SIL-1 Certified MX 43 is a Flexible, High Quality, Easy to Use Gas Detection System
Fully scalable, and designed to functional safety performance level 1 standards, the MX 43 is an analog and digital controller that continuously measures and controls gases in the atmosphere. The MX 43 gas detector manages both digital lines and analog channels and covers all needs for a wide variety of gas monitoring applications. The MX 43 digital technology allows up to 32 detectors to be distributed on 8 lines for increased cost savings.
MX52 2- 16 Channel Gas Detection Controller
The MX 52 control unit allows various detectors to be connected and monitored. Any gas detector from Teledyne Gas and Flame Detection or any other 4-20 mA device can be monitored and controlled. The modular design and flexibility enable this MX 52 gas detection equipment to be adapted to your exact requirements.
MX62 64 Channel Gas Detection Controller
An attractive solution for gas and flame detection needs, the MX 62 is a modular and flexible controller that is easy to install and reduces operational costs. The MX 62 system meets the requirements of ATEX 100 A and offers the high level of security required by SIL2 and SIL3 rated systems.
Detecting the right flame for the right application is critical when protecting your plant or process from Fire. Different fires require different technologies to accurately detect them, Whether it be UV, UV/IR, Single IR, IR3 or Intelligent Visual Flame technologies, ProDetec can offer expertise in selecting the correct detection method.
FDS300 Intelligent Visual Flame Detector
Designed for hazardous industries where fast optical flame detection is critical and nuisance alarms are not an option!
The MICROPACK FDS300 is an explosion-proof visual flame detector. It processes live video images to detect the characteristic properties of flames visually, by means of its flame detection algorithms and on-board digital signal processing.
FDS301 Intelligent Visual Flame Detector
Designed for hazardous industries where fast optical flame detection is critical and nuisance alarms are not an option!
The MICROPACK FDS301 is an explosion proof visual flame detector. It processes live video images to detect the characteristic properties of flames visually, by means of its FM and SIL 2 certified flame detection algorithms and on-board digital signal processing. It is the safest and most advanced flame detector on the market today, and its installation track record in the harshest of locations around the globe has proven the instrument to be extremely robust.
FDS303 Multi Spectrum IR Flame Detector
Designed for hazardous industries where fast fire detection is critical and nuisance alarms are not an option!
The MICROPACK FDS303 is an explosion-proof multi-spectrum IR flame detector. The device delivers superior performance, responding to hydrocarbon liquid fuel and gas fires at long distances.
The FDS303 has been tested by Factory Mutual to detect a hydrocarbon fuel pan fire at 60 m (~ 200 feet) in 5 seconds.
DF-TV7 IR3 Flame Detector (SIL3)
The MultiFlame DF-TV7–T is a multi-spectrum infrared flame detector using three wavelengths. The MultiFlame DF-TV7-T responds to hydrocarbon fires and is the right choice for operation in dirty environments or for detection of smoky fires.
DF-TV7 UV2IR Flame Detector (SIL2)
The Simtronics DF-TV7 is a combined ultraviolet / infrared flame detector offering excellent flame detection whilst maintaining outstanding false alarm immunity. The UV/2IR Multi Flame DF-TV7 is designed to respond to unwanted hydrocarbon fires, whilst maintaining a high degree of false alarm immunity. The DF-TV7 flame detector uses combined ultraviolet/infrared (UV-2IR) optical technology that provides industry-leading immunity to false alarms based on the two IR channel design.
The device offers a wide range of output options, as standard and is suitable for use in SIL 2 applications. The detector can be configured to communicate with a wide range of fire panels, controllers, and PLCs and offer HART 7 and Syntel (Lonworks) protocols for addressable event monitoring. The devices come standard with a configurable 4-20mA or 0-22mA (PLC) output, two configurable alarm relays, and two detector status LEDs.
All Multi Flame detectors are equipped with a continuous optical lens auto-check to ensure that the optical path is clear and that the detector functions properly. Sensors can be replaced easily in the field without removing any cable glands. Devices are easy to test and configure using a TLU wireless handheld unit that is approved for use in hazardous areas. The TLU can also be used for wireless testing of the optical and output circuits. The TLU can also be used for wireless testing of the optical and output circuits.
Linear Heat Detection
The simple and proven technology of digital Linear Heat Detection (LHD) cable, makes it a product of choice for difficult and challenging applications where other technologies struggle to work. With it’s ease of installation and low maintenance it also provides a cost effective solution where project expenditure requires to be kept at a minimum.
The sensing cable is formed from a pair of twisted steel conductors each with temperature sensitive insulation and then an overall Nylon outer sleeve. When the temperature sensitive insulation reaches it’s predetermined alarm temperature the two conductors short together providing the digital or switched signal. The cable can be connected to any unit capable of monitoring a switched signal, i.e. Conventional fire panel, addressable switch monitor unit or PLC.
Digital Interface Module
The Digital Interface Module (DIM) monitors the Linear Heat Detection (LHD) cable for both Fire and Fault (open circuit) conditions. Using an additional series resistor, it can also offer discrimination of a short circuit fault on the interposing field wiring.
With the ability to monitor up to 5000m for both Fire and Fault conditions the DIM enhances any fire detection capability and allows an appropriate action to be taken.
The DIM has volt free relay outputs for Fire and Fault which can be configured for connecting directly into a conventional fire alarm panel or addressable interface module.
As well as having Fire and Fault indicators built in, it has two pairs of outputs for driving remote LED indicators for Fire and Fault.
DLI-2K Digital Location Interface (Monitoring Distance 2Km)
The Digital Location Interface (DLI) monitors the Linear Heat Detection cable and identifies the location of the active alarm. The distance is then displayed in meters on the 3½ digit LCD.
The DLI is able to monitor up to 2000m for both Fire and Fault conditions. This enhances any fire detection capability and allows an appropriate action to be taken.
The DLI also offers flexible interface options, designed as a two-wire device for connecting directly into a conventional fire alarm panel. It also has the ability to signal via volt free relay contacts for Fire and Fault, plus a 4-20 mA output.
IP 65 weatherproof lockable Polycarbonate enclosure with M20 and M25 cable gland knockouts.
DLI-10K Digital Location Interface (Monitoring Distance 10Km)
The Digital Location Interface (DLI) monitors the Linear Heat Detection (LHD) cable and identifies the location of the active alarm. The distance in meters is then displayed on the 4-digit LCD.
The DLI is able to monitor up to 10,000m for both Fire and Fault conditions the DLI enhances any fire detection capability and allows an appropriate action to be taken.
There are flexible interfacing options, designed as a two-wire device for connecting directly into a conventional fire alarm panel, it also has the ability to signal via volt free relay contacts for Fire and Fault, plus a 4-20 mA output.
IP 65 weatherproof lockable Polycarbonate enclosure with M20 and M25 cable gland knockouts.
End Of Line Units
End Of Line (EOL) units are used in conjunction with the Interface modules to terminate the Linear Heat Detection (LHD) cable and contain the appropriate EOL component or device. This allows the modules to monitor the LHD for any open circuit fault conditions. Units fitted with test switches allow the alarm system to be tested for Fire and Fault conditions without the need for destructive use of any LHD. The units are available in several different materials to suit different applications and environments.
ProDetec can offer our customers innovative portable gas detectors that offer greater reliability, improved productivity, and better cost-efficiency to protect your workers from potential gas hazards. These gas detectors can be readily calibrated and tested on site with the aid of Automated Calibration and Bump Testing Stations
Multi Gas Clip Simple Plus
No charging ever! 3 Year runtime. Reliably test for hydrogen sulphide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL) with this simple-to-use and simple-to-maintain detector. Just turn it on and have worry free assurance of protection against toxic gases 24/7 for three full years.
Multi Gas Clip Simple
4 gas detector with 2 year runtime. No charging ever! Reliably test for hydrogen sulphide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL) with this simple-to-use and simple-to-maintain detector. Just turn it on and have worry free assurance of protection against toxic gases 24/7 for two full years.
PS200 4 Gas Monitor
The PS200 Multi Gas Detector combines quality, ruggedness, and advanced technology in a user friendly, portable gas monitor. It is compact, lightweight, water resistant, extremely robust, and is certified to multiple international and regional standards.
The PS200 can measure any combination of LEL, O2, CO and H2S making it suitable for a wide range of personal monitoring and confined space applications.
In addition to extensive data logging capabilities, the PS200 is available with an optional internal pump and an extensive range of accessories to meet a wide variety of user applications.
PS500 5 Gas Monitor
Designed by our customers, this robust and accurate gas detector provides unrivalled protection in confined space applications. The PS500 can be tailored to detect up to five gases with its toxic and catalytic sensors, photo ionisation detectors, and infrared capabilities. “Plug and Play” option allows the customer to “plug in” a new board with a different gas range.
Multi Gas Clip Infrared
The MGC IR detects combustible gases (LEL), hydrogen sulphide (H2S), carbon monoxide (CO) & oxygen (O2). The MGC IR can go a full 2 months without a charge, even without ever having to be turned off. Shut down the detector nightly and the battery can last up to 4 months.
Multi Gas Clip Pump Infrared
Like the MGC IR, the MGC IR Pump uses low-power photometric infrared technology to detect combustible gases (LEL) rather than age-old pellistor technology. The MGC IR Pump uses an IR source which conserves power and helps the battery last and last.
Single Gas Clip Plus
The Single Gas Clip Plus, is a maintenance free handheld gas detector with built in “Hibernate” mode for detecting hydrogen sulphide (H2S) or carbon monoxide (CO). “Hibernate” mode allows users to place this disposable single gas detector in a rested state when not in use.
Single Gas Clip
Whether it’s the hottest or the coldest environment, our Single Gas Clip is designed and tested to provide worker safety in the harshest working conditions. Gases available are hydrogen sulphide (H2S), carbon monoxide (CO), oxygen (O2).
Protege ZM Single Gas Monitor
The GMI Protege ZM Single Gas Monitor is an easy-to-use, zero maintenance gas detection solution that delivers high performance in a small, ergonomically designed package. It is available in oxygen, carbon monoxide and hydrogen sulphide single gas models. This single gas monitor is incredibly reliable, giving industrial workers and first responders the confidence to focus on the task at hand, not on their equipment.
MGC Simple Clip Dock
The Gas Clip Technologies MGC Simple Clip Dock is an all-in-one, stand-alone docking station designed for maximum testing efficiency and portability. It tests up to four detectors simultaneously, reducing the testing time and gas usage.
Multi Gas Clip Dock
The Gas Clip Technologies MGC Dock is an all-in-one stand-alone docking station designed for maximum testing efficiency and portability. It tests up to four detectors simultaneously, reducing the testing time and gas usage.
MGC Pump Clip Dock
The Gas Clip Technologies MGC Pump Clip Dock is an all-in-one stand-alone docking station designed for maximum testing efficiency and portability. It tests up to four detectors simultaneously, reducing the testing time and gas usage.
Single Gas Clip Dock
Gas Clip Technologies Single Gas Clip Dock is an all in one docking station designed for maximum testing efficiency and portability. Housed in a rugged case with robust USB memory, this station will be able to accurately test and record all monitor data while reducing the testing time and gas usage.
PS200 ABC Station
The multi-functional Auto Bump/Calibration station provides simple but intelligent testing and calibration of the PS200 portable gas detector. Easy to use, with a durable, user friendly design, this automated test station offers high performance from a PC or stand-alone unit.
PS500 ABC Station
To provide accurate performance and results, the PS500 has to be properly used and maintained. The Auto Bump & Calibration Station (ABC) provides bump testing, calibration and data management options and is compact, robust and intuitive to use.
LaserGas™ III Portable
LaserGas™ III HF Portable analyser is compact, lightweight and battery powered instrument which is ideal for HF leakage detection. With on-board pump and connections for Teflon tubing the target gas is continuously transferred into the internal measurement cell.
The instrument´s low power design gives long operating time on each battery cycle. The analyser provides reliable operation with instantaneous response and sufficient dynamic range to measure from sub ppm to several hundred ppm HF concentrations.
At ProDetec we can supply specialised gases and gas mixtures to meet various and specific requirements. We work with you to understand your application and analyse your consumption patterns. This way we can offer the correct cylinder size that maximises your efficiency while minimising costs.
44 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder
Recyclable 44 litre cylinders available for reactive gas mixtures, supplied with either a single gas or a complex blend.
Most commonly supplied in 4 or 5 gas mixtures such as CH4, O2, CO, H2S with either SO2 or CO2
Also available in single fills containing H2S, NH3, PH3, HCN, HCL, SO2, NO2, NO in either air or nitrogen. Some reactive gases will have a shorter life – typically 12 months.
66 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder
Recyclable 66 litre cylinders available for reactive gas mixtures, supplied with either a single gas or a complex blend.
Most commonly supplied in 4 or 5 gas mixtures such as CH4, O2, CO, H2S with either SO2 or CO2
Also available in single fills containing H2S, NH3, PH3, HCN, HCL, SO2, NO2, NO in either air or nitrogen. Some reactive gases will have a shorter life – typically 12 months.
103 Litre Steel Non-Reactive Single Gas Calibration Gas Cylinder
Disposable cylinders available for non reactive gas mixtures, supplied with either a single gas up to three non reactive gas mixtures
Most commonly supplied in single fills containing Argon, Benzene, Butane, Carbon Dioxide, Carbon Monoxide, Ethane, Ethylene, Freon, Helium, Hexane, Hydrogen, Isobutane, Isobutylene, Methane, Nitrogen, Oxygen, Pentane, Propane, Toluene in either Air or Nitrogen backgrounds. Warranty on these gases is 48 months.
116 Litre Aluminium Recyclable Reactive Multi Mixture Calibration Gas Cylinder
Recyclable 116 litre cylinders available for reactive gas mixtures, supplied with either a single gas or a complex blend.
Most commonly supplied in 4 or 5 gas mixtures such as CH4, O2, CO, H2S with either SO2 or CO2
Also available in single fills containing H2S, NH3, PH3, HCN, HCL, SO2, NO2, NO in either air or nitrogen. Some reactive gases will have a shorter life – typically 12 months.
Regulators and Accessories
Regulators for non-refillable cylinders are available in a number of different configurations including fixed flow, push button, on-demand flow and variable flow models.
Gas Recycling Program
Once the calibration gas cylinders are relieved of pressure they are NOT considered hazardous material or waste. Nearly all of our mixtures contain only a very small amount of a hazardous chemical(s) as a minor component in the gas mixture requested. The fact that it is such a small amount (usually in the ppm range) always precludes the gas mixture from ever being classified as hazardous.
Our calibration gas cylinder recycling program is an environmentally-friendly way to reduce waste caused by empty cylinders. We offer a free, easy way to return used cylinders for future use.
Gas analysers based on TDLAS have been used for many industrial process control and emission monitoring applications and are well-accepted throughout multiple industries. The advantages of performing measurements directly in the process (in situ) include fast response, high selectivity and high sensitivity, which makes efficient process control possible. Furthermore, in situ measurements require little maintenance and thus lower operational expenditures.
LaserGas™ III Single Path
LaserGas™ III SP is the third generation in-situ analyzer, designed for safety applications with a special focus on SIL-applications and Ex-d. A compact sized instrument which is easy to install. The instrument is a placed in a sealed housing which eliminates the need for instrument purging. The instrument does not require regular maintenance.
The monitor is mounted directly onto flanges, which include purge gas connections and a tilting mechanism for easy alignment. Continuous purge flow prevents dust and other contamination from settling on the optical windows. Once power and data lines are connected, measurements are performed in real-time.
LaserGas™ II Single Path
LaserGas™ II SP (Single Path) is a non-contact optical measurement method also known as in-situ. The analyser is suitable for variety of gases and process conditions, including dual gas measurements.
Laser Gas™ II SP has also a wide range of Ex-certifications, including IECEx, ATEX, CSA.
The instrument does not require any consumables and does not require regular maintenance. The absence of extractive conditioning systems further improves availability of the measurements and eliminates errors related to sample handling.
Once power, data lines and purge are connected, the instrument is ready to use and measurements are performed in real-time.
LaserGas™ iQ2
LaserGas™ iQ2 analyser is the first to measure up to four gases (O2, CO, CH4, H2O) and temperature depending on configuration, which eliminates the need for multiple units for combustion analysis.
The cutting-edge design and ground-breaking functionality ensure that the instrument delivers unmatched reliability and durability. Customers may replace existing analysers where explosion risks or high maintenance issues are a huge concern.
LaserGas™ Q ICL
Unlike the previous generations of LaserGas™ products, the LaserGas™ Q family measures in the mid-infrared spectrum which allows for better detection limits. As well as detection of gases not obtainable with the more common near-infrared spectroscopy.
The sensor has low maintenance cost and does not require regular maintenance. The absence of extractive conditioning systems further improves availability of the measurements and eliminates errors related to sample handling.
The monitor is mounted directly onto flanges, which include purge gas connections and a tilting mechanism for easy alignment. Continuous purge flow prevents dust and other contamination from settling on the optical windows. Once power and data lines are connected, measurements are performed in real-time.
Monitor your process water / process waste water for traces of oil by using an oil-in-water monitor. This ensures that process faults are detected at an early stage and/or environmental pollution resulting from exceeding the limits is avoided.
OilGuard 2W
The instrument is used for monitoring oil traces in raw, surface run-off, process and wastewater. As a result of the non-contact (free-fall) measurement, there is no drift in readings as a result of window fouling. Another benefit of this design feature is the extremely low need for maintenance. This instrument is for non-hazardous applications.
No external operator interface is required as the colour touch-pad is integral to the analyser.
If the environment is hazardous, please refer to the OilGuard Ex
As has been documented in many journals and papers, the rim seal around the entire circumference of the floating roof tank presents a major fire hazard. Floating Storage Tanks usually contain highly flammable products which can potentially cause catastrophic fires. When the fire is not detected early it can cause significant loss of plant, down time of production and in severe situations even risk to life. These can have a large financial or environmental impact.
BM25 Wireless Area Monitor
The BM25 packs the benefits of a fixed system area monitor into a rugged, user-friendly and transportable instrument. It was designed to detect one to five gases for mobile or temporary work applications, team protection, area surveillance or places where fixed detection systems are not suitable.
FDS301 Intelligent Visual Flame Detector
Designed for hazardous industries where fast optical flame detection is critical and nuisance alarms are not an option!
The MICROPACK FDS301 is an explosion proof visual flame detector. It processes live video images to detect the characteristic properties of flames visually, by means of its FM and SIL 2 certified flame detection algorithms and on-board digital signal processing. It is the safest and most advanced flame detector on the market today, and its installation track record in the harshest of locations around the globe has proven the instrument to be extremely robust.
Linear Heat Detection
The simple and proven technology of digital Linear Heat Detection (LHD) cable, makes it a product of choice for difficult and challenging applications where other technologies struggle to work. With it’s ease of installation and low maintenance it also provides a cost effective solution where project expenditure requires to be kept at a minimum.
The sensing cable is formed from a pair of twisted steel conductors each with temperature sensitive insulation and then an overall Nylon outer sleeve. When the temperature sensitive insulation reaches it’s predetermined alarm temperature the two conductors short together providing the digital or switched signal. The cable can be connected to any unit capable of monitoring a switched signal, i.e. Conventional fire panel, addressable switch monitor unit or PLC.
Digital Interface Module
The Digital Interface Module (DIM) monitors the Linear Heat Detection (LHD) cable for both Fire and Fault (open circuit) conditions. Using an additional series resistor, it can also offer discrimination of a short circuit fault on the interposing field wiring.
With the ability to monitor up to 5000m for both Fire and Fault conditions the DIM enhances any fire detection capability and allows an appropriate action to be taken.
The DIM has volt free relay outputs for Fire and Fault which can be configured for connecting directly into a conventional fire alarm panel or addressable interface module.
As well as having Fire and Fault indicators built in, it has two pairs of outputs for driving remote LED indicators for Fire and Fault.
DLI-2K Digital Location Interface (Monitoring Distance 2Km)
The Digital Location Interface (DLI) monitors the Linear Heat Detection cable and identifies the location of the active alarm. The distance is then displayed in meters on the 3½ digit LCD.
The DLI is able to monitor up to 2000m for both Fire and Fault conditions. This enhances any fire detection capability and allows an appropriate action to be taken.
The DLI also offers flexible interface options, designed as a two-wire device for connecting directly into a conventional fire alarm panel. It also has the ability to signal via volt free relay contacts for Fire and Fault, plus a 4-20 mA output.
IP 65 weatherproof lockable Polycarbonate enclosure with M20 and M25 cable gland knockouts.
DLI-10K Digital Location Interface (Monitoring Distance 10Km)
The Digital Location Interface (DLI) monitors the Linear Heat Detection (LHD) cable and identifies the location of the active alarm. The distance in meters is then displayed on the 4-digit LCD.
The DLI is able to monitor up to 10,000m for both Fire and Fault conditions the DLI enhances any fire detection capability and allows an appropriate action to be taken.
There are flexible interfacing options, designed as a two-wire device for connecting directly into a conventional fire alarm panel, it also has the ability to signal via volt free relay contacts for Fire and Fault, plus a 4-20 mA output.
IP 65 weatherproof lockable Polycarbonate enclosure with M20 and M25 cable gland knockouts.
End Of Line Units
End Of Line (EOL) units are used in conjunction with the Interface modules to terminate the Linear Heat Detection (LHD) cable and contain the appropriate EOL component or device. This allows the modules to monitor the LHD for any open circuit fault conditions. Units fitted with test switches allow the alarm system to be tested for Fire and Fault conditions without the need for destructive use of any LHD. The units are available in several different materials to suit different applications and environments.
An Ultrasonic does not detect specific values of LEL or ppm, rather, it responds to the sound generated by escaping gas at ultrasonic frequencies. Such signals are generated when leakage occurs at sonic velocity; this requires a driving pressure of at least 2 barA. The detected sound is proportional to the leak rate (mass flow rate). In basic terms, the greater the leak rate (large leak), the greater the ultrasound emitted. Ultrasonic gas leak detectors complement traditional gas detection methods used in refineries, gas plants and offshore installations.
Observer-i Ultrasonic Gas Leak Detector
Instantly detect pressurised gas leaks with this high-precision, omni-direction acoustic detector utilising Gassonic ultrasonic technology. Works even when traditional methods of gas detection are unsuitable or dependent on ventilation. Features Artificial Neural Network (ANN) technology that distinguishes between real gas leaks and false alarm sources without requiring any in-field training. The Observer-i UGLD provides an industry-leading detection range (up to 28 m) reducing the number of detectors required. Ideal for use in complex, outdoor pipeline systems.
Wireless Gas Detection Systems are economically deployable in both permanent and temporary installations. Proprietary “self-healing mesh” technology operates at 2.4 GHZ and conforms to non licensed radio frequency appliance usage around the world. Wireless network integrity and security is accomplished using direct sequence spread spectrum DSSS programming topology. Wireless applications can be as simple as a single field device communicating with a host display or any number of field devices forming a network of subscribers.
BM25 Wireless Area Monitor
The BM25 packs the benefits of a fixed system area monitor into a rugged, user-friendly and transportable instrument. It was designed to detect one to five gases for mobile or temporary work applications, team protection, area surveillance or places where fixed detection systems are not suitable.
MCX-32 Smart Wireless Controller
The MCX-32 is a multi-channel integrated control system with a capacity of 64 active channels. It can receive and supervise inputs from a wide range of field devices with either a 4-20mA DC or serial output. The standard serial protocol is RS-485 Modbus RTU. This unique system design features “auto-configuration” of addressable devices that are in a device library. The Model MCX-32 controller provides a unique combination of “auto configuration” simplicity and ease of use with customizable expansion capabilities.
CXT SmartWireless Low Powered Gas Detection Sensors
The CXT Range of Wireless gas detection sensors are rated for IEC EX hazardous areas. These advanced field devices consist of a CXT low power gas detection sensor and wireless transceiver packaged in a single enclosure. Power is provided by a disposable “D” cell battery pack with a run time of 9 months and solar panel providing continuous operation.
Site Sentinel CXT Wireless Controller
The Detcon SmartWireless® CXT controller is a multi-channel mobile gas detection control system that may be wall mounted or mounted on a Detcon tripod accessory. The CXT can be utilised for
self-contained gas detection, display/alarm system package or wirelessly connected to the main network. The controller offers a non-intrusive magnetic interface with back-lit LCD display that supports either wireless or a hard wire connection to gas detection sensors. The CXT is equipped with an auto configure system to automatically search for Detcon equipment associated with the controller.
SmartWireless Site Sentinel CX Sensor Station
The SmartWireless Site Sentinel CX sensor station is an accessory to any Detcon wireless RXT transceiver or wireless controller and is easily and economically deployable in both permanent and temporary installations. The CX wirelessly transmits the data from up to 4 wired gas detectors back to wireless controller and includes a battery that powers the radio, alarm devices, and the attached sensors. The Sentinel CX is compatible with Detcon’s Model RXT transceivers. Flexible and expandable, a Site Sentinel network can include up to 32 devices and consist of any combination of wireless and/or wired sensors, one or more Site Sentinel control panels, and alarm warning devices.
SW-AV1-DV2 Wireless Audio/Visual Alarm
Detcon SmartWireless® audio-visual alarm stations are easily and economically deployable in both permanent and temporary installations. These devices feature a battery powered audio-visual alarm station designed as a wireless cordless system component.
SW-AV2-DV2 Wireless Audio/Visual Alarm
Detcon SmartWireless® audio-visual alarm stations are easily and economically deployable in permanent and temporary installations. These devices have a battery-powered audio-visual alarm station designed as a component of a wireless system.
Audible, Visual Sounders and Sirens are used for alert and alarm purposes in the process, mining and industrial applications
BExS110 Ex d Alarm Horn – Radial Omni-directional
The flameproof BExS110 alarm sounders are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards.
The BExS110-R is an alarm sounder featuring a radial omni-directional horn that disperses the alarm tones radially. Ideal for applications requiring a compact audible signalling solution.
The BEx explosion proof Ex d range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with chromate and powder coat finish.
A105N Alarm Sounder
The A105N is a high output, 112dB(A) alarm sounder. UL and GOST-R approved and tested to EN54-3 for CPR compliance (89/106/EEC) for fire alarm use. For marine applications the A105N is MED approved.
Low current consumption and high SPL in a robust fire retardant IP66 housing ensure the A105N is suitable for all general signalling applications including fire, security and process control.
A100 Alarm Sounder
The A100 is a compact, high output, 104dB(A) alarm sounder. CPR complaint, EN54-3 tested and UL approved. Featuring 32 alarm tone frequencies and 3 remotely activated stages/channels.
Low current consumption and high SPL in a robust fire retardant housing ensure the A100 is suitable for all general signalling applications including fire, security and process control. The A100 is a member of the versatile AlertAlarm family of industrial alarm horn sounders – also available with Xenon, AL100X or LED beacons, AL100H.
A112N Alarm Sounder
The A112N is a high output, 119dB(A) alarm sounder. UL and GOST-R approved and tested to EN54-3 for CPR compliance (89/106/EEC) for fire alarm use. For marine applications the A112N is MED approved.
High SPL in a robust fire retardant IP66 housing ensure the A112N is suitable for all general signalling applications including fire, security and process control.
A121 Alarm Sounder
The A121 is a very high output, 126dB(A) alarm sounder. UL and GOST-R approved and tested to EN54-3 for CPR compliance (89/106/EEC) for fire alarm use.
High SPL in a robust, fire retardant IP66 housing ensure the A121 is suitable for all general signalling applications including fire, security and process control.
A131 High Level Audible Warning System
The A131 is a high output 131dB(A) @ 1 metre electronic siren in a compact and easy to install package. Using up to four speakers, it can be mounted in a variety of ways for applications with sound coverage requirements up to 300m.
The A131 modular system is ideal as a plant alarm to cover outdoor locations, areas with high background noise or smaller COMAH (Seveso II) applications. Offering a choice of three alarm stages, selected from a choice 45 tones including many national standard tones, it can be incorporated in fire, security and general alarm systems where existing equipment is not powerful enough or the system needs expanding.
A141 High Level Audible Warning System 141dB(A)
The A141 is the latest in a new generation of high output electronic sounders from E2S which are ideal for wide area and disaster warning applications requiring sound coverage up to 750m.
With a choice of 45 standard warning tones including many international signals the A141 is also available in a ‘Stage Programmable’ version which can offer up to 4 remotely activated stages of alarm. Typical installation include COMAH (Seveso II) Alarm, Toxic Gas Release, Fire, Security, Flood Warning, Tsunami Alert and Civil Defence.
A151 High Level Audible Warning System
E2S offer a range of solutions for disaster and outdoor warning.
BExS110 Explosion Proof Alarm Horn Sounder
The flameproof BExS110 alarm sounders are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards. Available as SIL 1 and SIL 2 compliant.
Sound level outputs of up to 117dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages.
The BEx explosion proof Ex d range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with chromate and powder coat finish.
Available in MED approved and SIL2 compliant versions.
For fire applications the BExS110D 24V dc siren is CPD EN89/106/EEC compliant (EN54-3 tested).
BExS120 Explosion Proof Flare Horn Alarm Sounder
The flameproof BExS120 alarm sounders are suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards.
Sound level outputs are up to 123dB(A) at 1 metre with a choice of 32 alarm tones and 3 remotely selectable stages.
The BEx explosion proof Ex d range features enclosures manufactured from corrosion proof, marine grade copper free LM6 aluminium with chromate and powder coat finish.
For fire applications the BExS120D 24V dc siren is CPD EN89/106/EEC compliant (EN54-3 tested).
BExH120 ‘Hootronic’ Explosion Proof Alarm Horn
The flameproof BExH120 Hootronic Siren is suitable for Zone 1, 2, 21 & 22 applications. Approved to IECEx, ATEX, Ex EAC and INMETRO standards. The BExH120 authentically reproduces the traditional sounds of electro-mechanical devices whilst providing a significantly higher level of performance and reliability.
The E2S Hootronic series of products faithfully reproduce the sounds made by legacy electro-mechanical signalling devices but in a modern, reliable and cost effective way. With output levels of up to 117.5dB(A) at 1 metre the BExH120 surpasses legacy electro-mechanical devices in performance and effectiveness, it is also continuously rated, requires zero maintenance and the signal quality will not degrade with age.
BEx Plated Assemblies
The BEx explosion proof Ex d family of alarm horn sounders, Xenon strobe and LED beacons can be configured to create sets of status lights suitable for onshore and offshore applications.
Mounted onto a stainless steel backplate, E2S can offer up to 5 different components complete with the option of Exe Junction Box to simplify installation. Status lights configurations can utilise the high power BExBGL2 LED beacon. Warning beacons utilising Xenon strobe technology – available in 5, 10, 15 and 21J outputs (up to 485 Cd) and providing effective warning in all conditions.
Manual alarm call points are designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by operating the push button or break glass the alarm signal can be raised.
BExCP3-BG Break Glass Manual Call Point
The BExCP3-BG break glass manual call points are designed for the harshest of environments and approved for Zone 1, 2, 21 and 22 explosion proof hazardous areas for the control of fire and gas alarm systems. SIL2 compliant to IEC61508 (2010).
The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium with a chromated and powder coat finish. Available with and without monitoring resistors all versions are certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The break glass element features a safety membrane and is designed to snap ensuring the no glass fragments are released during activation. A hammer is available as an accessory if required by local code.
BExCP3-PB Push Button Manual Call Point
The BExCP3-PB push button manual call points are designed for the harshest of environments and approved for Zone 1, 2, 21 and 22 explosion proof hazardous areas for the control of fire and gas alarm systems. SIL2 compliant to IEC61508 (2010).
The BEx range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium with a chromated and powder coat finish. Available with and without monitoring resistors all versions are certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The BExCP3-PB is user re-settable by rotating the push button.
IS-CP4-PB Push Button Manual Call Point
The IS-CP4-PB push button manual call points are designed for the harshest of environments and approved for Zones 0, 1, 2, 21 & 22 requiring hazardous area intrinsically safe equipment for the control of fire and gas alarm systems. SIL2 compliant to IEC61508 (2010).
The IS-CP4 range features enclosures manufactured from corrosion proof, marine grade, copper free LM6 (A413) aluminium which is chromated and powder coated. Available with and without monitoring resistors all versions are certified to IECEx and ATEX standards with additional INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The IS-CP4-PB is user re-settable by rotating the push button.
GNExCP6-BG Break Glass Manual Call Point
Available with optional EOL or series resistors, diode or Zener diodes and an LED indicator. Also with either single or double pole change over switches. Certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The break glass element features a safety membrane and is designed to snap ensuring the no glass fragments are released during activation. A hammer is available as an accessory if required by local code.
The flameproof GNExCP6-BG break glass manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. The robust, lightweight GRP enclosure is UV stable and provides a corrosion free initiation solution for harsh and hazardous applications on and offshore.
GNExCP6-PB Push Button Manual Call Point
The flameproof GNExCP6-PB push button manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. The robust, lightweight GRP enclosure is UV stable and provides a corrosion free solution for initiation in harsh and hazardous applications on and offshore.
Available with optional EOL or series resistors, diode or Zener diodes and an LED indicator. Also available with either single or double pole change over switches. Certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The GNExCP6-PB is user re-settable by rotating the push button.
GNExCP6-PT Push Button Tool Reset Call Point
The flameproof GNExCP6-PB tool reset push button manual call points are approved for Zone 1, 2, 21 and 22 hazardous areas for the control of fire and gas alarm systems. The robust, lightweight GRP enclosure is UV stable and provides a corrosion free solution for initiation in harsh and hazardous applications on and offshore.
Available with optional EOL or series resistors, diode or Zener diodes and an LED indicator. Also available with either single or double pole change over switches. Certified to IECEx and ATEX standards with additional PESO, INMETRO and Ex EAC approvals. The push button mechanism is protected by a spring loaded cover therefore the switch requires a two-action activation. The GNExCP6-PT is user re-settable via the use of the special key supplied with the unit.
Measuring density of a sample is an important quality parameter of both raw materials and finished products. Various techniques enable the density of solid, viscous and liquid materials to be accurately determined e.g. metals, plastics, chemicals, lubricants and food.
SonaTec
SONATEC is a highly precise sound velocity sensor for determination of sound velocities and concentrations (e. g. of acids, caustics, emulsions or solvents). The sensor can be used for instance for phase detection and for monitoring of crystallization processes.
RhoTec
RHOTEC is a highly precise density sensor for determination of densities and concentrations (e. g. of acids, caustics, emulsions or solvents). The sensor can be used for instance for phase detection and for monitoring of crystallization processes.
CombiTec
COMBITEC is used for 3-component solutions to measure simultaneously density, sound velocity and concentration e. g. in a mixture of acid and salt in water or in systems such as sulfuric acid/oleum or methanol/formaldehyde.
RhoTec L
RHOTEC L is a highly precise sensor for determination of densities and concentrations (e. g. of extract, alcohol, sugar, acids, caustics, and solvents) according to the oscillating U-tube principle. The samples are manually injected into the sensor. The instrument is designed for laboratory applications requiring maximum sensitivity and highest accuracy.
Oxygen measurement in boiler feed water and in protective atmospheres
OxyTrans
Optical Oxygen Sensor
The Oxygen concentration transmitter OxyTrans TR measures continuously and accurately measures the content of oxygen in liquids and gases. While the OxyTrans was originally designed for breweries, it has found service in other industries demanding these levels of accuracy, for example power plants or bioreactors.
The O2-concentration can be displayed in different units like ppb, ppm, %oxygen, etc.
The OxyTrans is available as either a transmitter installed inline (with the TR designation) or a handheld Mobile device (with the M suffix).
Optimize your process with a continuous concentration measurement of different substances in liquids. A typical application is to monitor waste water for traces of phenol. Effluent from mineral oil processing plants, plastics production etc. contain a high amount of phenol and have to be treated prior to being discharged into the environment.
CombiTec
COMBITEC is used for 3-component solutions to measure simultaneously density, sound velocity and concentration e. g. in a mixture of acid and salt in water or in systems such as sulfuric acid/oleum or methanol/formaldehyde.
SonaTec
SONATEC is a highly precise sound velocity sensor for determination of sound velocities and concentrations (e. g. of acids, caustics, emulsions or solvents). The sensor can be used for instance for phase detection and for monitoring of crystallization processes.
RhoTec
RHOTEC is a highly precise density sensor for determination of densities and concentrations (e. g. of acids, caustics, emulsions or solvents). The sensor can be used for instance for phase detection and for monitoring of crystallization processes.
This is mainly for thermal power houses, IGCC (Integrated coal Gasification Combined Cycle), etc. Air-fuel ratio control is very strict for some high-grade gas turbines so that gas turbines can be sustainably used with maximum combustion efficiency
OHC 800
Explosion Proof Calorimeter
The OHC-800 is an explosion-proof calorimeter. According to measured calorific values, 4 – 20 mA signals and digital signals are output. The calorimeter is used for the purposes of calorific value recording and device control by connecting it to a recorder or a programmable controller. The calorimeter has three contact outputs, and these are activated by malfunction etc. of the device.